The application of polyetheretherketone cage for lumbar fusion and the pedicle screw-based internal fixation in senile lumbar degenerative diseases
نویسندگان
چکیده
Objective: Our objective is to analyse the clinical effect and safety of Polyetheretherketone (PEEK) cage for lumbar fusion and the pedicle screw-based internal fixation in senile lumbar degenerative diseases, and further discuss the value of clinical application. Methods: 172 patients with senile lumber degenerative diseases admitted in our hospital during March, 2013-March, 2016 were selected, which were divided into the observation group and control group according to the random number method with 86 cases in either group. All the patients received lumbar inter-body fusion and pedicle screw-based internal fixation, in the observation group the material for inter-body infusion was PEEK and in the control group was titanium alloy. The surgery condition and complications in two groups were compared, and Japanese Orthopaedic Association (JOA) scores, Oswestry disability index (ODI) scores, ranges of joint motion, disc space heights and fusion rates were also observed to explore the applicable value of PEEK cage for lumbar fusion in senile lumbar degenerative diseases. Results: The operation time and intraoperative blood loss in two groups were not statistically different (P>0.05); there was no infection or nerve root injury and no looseness or breakage of internal fixation during follow-up, the bone graft recovered well. Compared with before surgery, the JOA scores were increased and ODI scores were decreased at 3 and 6 months after surgery, which were statistically significant (P<0.05), JOA and ODI scores between two groups at the same stages after surgery were not statistically different (P>0.05). Compared to before surgery, the motion ranges of instrumented segments in two groups were both decreased, and the motion ranges and the disc space heights of adjacent segments were both increased. After 6 months, the motion ranges of instrumented segments and adjacent segments and the disc space heights in the observation group were higher than the control group, which were statistically significant (P<0.05); The fusion rates of bone graft between two groups at the same stages after surgery were not statistically different (P>0.05). Conclusion: The clinical effects and safety of PEEK for lumbar fusion and the pedicle screw-based internal fixation in senile lumbar degenerative diseases are good. PEEK cage can better improve the range of joint motion and disc space height compared with titanium alloy cage, which is worthy of further application.
منابع مشابه
Comparative study of unilateral and bilateral pedicle screw fixation in posterior lumbar interbody fusion.
A prospective, randomized clinical study was performed to determine whether unilateral pedicle screw fixation was comparable with bilateral fixation in 1- or 2-segment lumbar interbody fusion. One hundred eight patients with lumbar degenerative diseases were randomly assigned to the unilateral (n=56) or bilateral (n=52) pedicle screw fixation group. Interbody fusion was performed in 1 or 2 leve...
متن کاملPolyetheretherketone (PEEK) Rods in Lumbar Spine Degenerative Disease: A Case Series.
STUDY DESIGN Retrospective case series. OBJECTIVE The purpose of our study was to retrospectively review the results of posterior lumbar fusion using polyetheretherketone (PEEK) rods. SUMMARY OF BACKGROUND DATA Pedicle screw and rod instrumentation has become the preferred technique for performing stabilization and fusion in the lumbar spine for degenerative disease. Rigid fixation with tit...
متن کاملThe SNAP trial: a double blind multi-center randomized controlled trial of a silicon nitride versus a PEEK cage in transforaminal lumbar interbody fusion in patients with symptomatic degenerative lumbar disc disorders: study protocol
BACKGROUND Polyetheretherketone (PEEK) cages have been widely used in the treatment of lumbar degenerative disc disorders, and show good clinical results. Still, complications such as subsidence and migration of the cage are frequently seen. A lack of osteointegration and fibrous tissues surrounding PEEK cages are held responsible. Ceramic implants made of silicon nitride show better biocompati...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملEarly Loosening of Spinal Rod in a Case of Degenerative Grade 1 Spondylolisthesis treated with Unilateral Pedicle Screw Fixation and Transforaminal Cage for Interbody Fusion
Introduction Unilateral pedicle screw fixation and transforaminal cage for interbody fusion are well-established form of treatment for lumbar spondylolisthesis. It is cost effective and has shown to have a comparable outcome to bilateral pedicle screw fixation. We present a case of unilateral pedicle screw fixation and transforaminal cage for interbody fusion in a patient of Grade 1 Degenerativ...
متن کامل