Determinants of myocardial response in CMR perfusion imaging using Gd-BOPTA (Multihance).

نویسندگان

  • Rolf Gebker
  • I Paetsch
  • M Neuss
  • B Schnackenburg
  • A Bornstedt
  • C Jahnke
  • O Gomaa
  • E Fleck
  • E Nagel
چکیده

PURPOSE Different centers and vendors use different sequences and contrast agent application schemes for MR myocardial perfusion imaging. The purpose of this study was to evaluate the role of different sequences, dosages, and injection speeds of contrast media for semiquantitative MR-perfusion assessment. METHODS In a pilot study with 58 consecutive patients three of the most commonly used sequences for MR myocardial perfusion imaging (T1-GrE, GrE-EPI or SSFP) were compared to each other in terms of peak myocardial enhancement and image quality. For the main part of the study dynamic first pass MR perfusion imaging (Philips Intera CV, Best, Tthe Netherlands) was performed in 24 patients using the most favorable sequence from the pilot study (SSFP) after peripheral i.v. administration of Gd-BOPTA during adenosine stress. Two doses (0.05 mmol/kg bw and 0.025 mmol/kg bw) and four different injection speeds (8, 4, 3, 2 ml/s) were used. Signal intensity time curves were determined in the LV and myocardial segments supplied by normal coronary arteries and correlation between LV and myocardial upslope as well as peak enhancement were noted. RESULTS The SSFP-sequence showed a higher peak enhancement when using 0.05 mmol/kg bw of Gd-BOPTA and a superior image quality for both dosage regimen compared with the other sequences and was consequently applied for the main study. A significant correlation was found between the upslopes in the LV and the myocardium (r square = 0.85, p < 0.001). However, LV and myocardial upslopes were largely independent of the dosage. Myocardial upslope was significantly slower at an injection rate of 2 ml/s compared to 3 and 4 ml/s. Higher Gd-doses led to significantly higher enhancement (p < 0.001). CONCLUSION In healthy myocardial segments, the myocardial upslope is mainly determined from the LV upslope. Both myocardial enhancement and upslope are largely independent from the injection rate of a contrast agent bolus as long as the injection speed is not below 3 ml/s. Myocardial enhancement, however, is dose dependent. Thus, a simple correction for LV upslope allows to normalize a wide variety of input parameters. Differences of myocardial upslope or peak signal intensity after correction should be mainly dependent on blood flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CMR myocardial infarct evaluation in a canine model by three different contrast agents

We evaluated R1 curves, CNR and scar visualization and quantification in a dog model of myocardial infarction by CMR, using three different contrast agents: Gadopentate dimeglumine (Gd-DTPA, Magnevist), Gadobenate dimeglumine (Gd-BOPTA, MultiHance), and Gadofosveset (Ablavar). Gd-DTPA showed better characteristics for myocardial scar visualization and quantification. Gadofosveset demonstrated l...

متن کامل

T1 mapping of the myocardium: intra-individual assessment of post-contrast T1 time evolution and extracellular volume fraction at 3T for Gd-DTPA and Gd-BOPTA

PURPOSE Myocardial T1 relaxation time (T1 time) and extracellular volume fraction (ECV) are altered in patients with diffuse myocardial fibrosis. The purpose of this study was to perform an intra-individual assessment of normal T1 time and ECV for two different contrast agents. METHODS A modified Look-Locker Inversion Recovery (MOLLI) sequence was acquired at 3 T in 24 healthy subjects (8 men...

متن کامل

Contrast-enhanced magnetic resonance cholangiography with Gd-BOPTA and Gd-EOB-DTPA in healthy subjects.

PURPOSE To evaluate the biliary enhancement dynamics of the two gadolinium chelates Gd-BOPTA (MultiHance) and Gd-EOB-DTPA (Primovist) in normal healthy subjects. MATERIAL AND METHODS Ten healthy volunteers were evaluated with both agents by magnetic resonance (MR) imaging at 1.5T using a breath-hold gradient-echo T1-weighted VIBE sequence. The relative signal intensity (SI) differences betwee...

متن کامل

Quantification of Gd-BOPTA uptake and biliary excretion from dynamic magnetic resonance imaging in rat livers: model validation with 153Gd-BOPTA.

OBJECTIVES We sought to develop and validate a pharmacokinetic model allowing description of the magnetic resonance (MR) signal intensity induced by the hepatobiliary contrast agent Gd-BOPTA and to quantify the overall Gd-BOPTA transport in rat liver. MATERIALS AND METHODS MR signal intensity was recorded during the perfusion of rat livers with Gd-DTPA, an extracellular contrast agent, and Gd...

متن کامل

Comparison of Gd-BOPTA and Gd-DPTA late gadolinium enhancement for visualizing scar, using valve enhancement as a surrogate for scar adjacent to blood

Introduction: Gadobenate dimeglumine (Gd-BOPTA; MultiHance; Bracco Imaging SpA, Milan, Italy) is a recently approved contrast agent with excellent properties for MR angiography (MRA) including a high relaxivity and slow clearance (1). A contrast agent with useful properties for both late gadolinium enhancement (LGE) and MRA is important for specific applications, e.g. for preand postpulmonary v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 7 3  شماره 

صفحات  -

تاریخ انتشار 2005