Photobleaching absorbed Rhodamine B to improve temperature measurements in PDMS microchannels.
نویسندگان
چکیده
Rhodamine B based fluorescence thermometry is commonly used in microfluidics to measure fluid temperatures in microchannels. Notable absorption of Rhodamine B into PDMS channel walls, however, causes difficulties in obtaining accurate temperature measurements due to a steady increase in the overall fluorescent signal. A simple and effective technique is reported that removes the fluorescent signal from absorbed Rhodamine B dye by means of photobleaching with a high intensity light source before taking images for thermometry analysis. The temperature field at the convergence of hot and cold streams in a Y-channel fabricated in PDMS/glass microfluidic chip is studied to demonstrate the execution of the photobleaching technique.
منابع مشابه
Method for microfluidic whole-chip temperature measurement using thin-film poly(dimethylsiloxane)/rhodamine B.
A novel method is presented for on-chip temperature measurements using a poly(dimethylsiloxane) (PDMS) thin film dissolved with Rhodamine B dye. This thin film is sandwiched between two glass substrates (one of which is 150 microm thick) and bonded to a microchannel molded in a PDMS substrate. Whole-chip (liquid and substrate) temperature measurements can be obtained via fluorescent intensity v...
متن کاملConvenient method for modifying poly(dimethylsiloxane) to be airtight and resistive against absorption of small molecules.
In this paper we present a simple and rapid method of modifying poly(dimethylsiloxane) (PDMS) surfaces with paraffin wax. PDMS that contains a layer of paraffin wax at its surface resists the absorption of hydrophobic molecules; we used fluorescence microscopy to confirm that paraffin-modified PDMS resists the absorption of rhodamine B. Furthermore, we demonstrated that microfluidic devices mad...
متن کاملJoule heating and its effects on electroosmotic flow in microfluidic channels
Joule heating is resulted from inevitable volumetric heating when an electric field is applied across conducting media and it would impose limitations to the performance of electrokinetic microfluidic devices. In this paper, the Joule heating and its effects on electroosmotic flow (EOF) in PDMS microfluidic channels are reported. 3D numerical simulation of the Joule heating induced temperature ...
متن کاملSimple method to enhance the photostability of the fluorescence reporter R6G for prolonged single-molecule studies.
For fluorescence-based single-molecule studies, photobleaching of the dye reporter often limits the time window over which individual molecules can be followed. As such, many strategies, for example, using a cocktail of chemical reagents, have been developed to decrease the rate of photobleaching. Herein, we introduce a new and highly effective method to enhance the photostability of one of the...
متن کاملTwo-photon thermal bleaching of single fluorescent molecules.
We have studied the fluorescence emission by two-photon excitation of four dyes widely used for bioimaging studies, rhodamine 6G, fluorescein, pyrene and indo-1 at the single molecule level. The single dye molecules, spread on a glass substrate by spin coating, show a constant fluorescence output until a sudden transition to a dark state very close to the background. The bleaching time that is ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lab on a chip
دوره 9 1 شماره
صفحات -
تاریخ انتشار 2009