An evaluation of the insertion and function of a new supraglottic airway device, the King LT, during spontaneous ventilation.

نویسندگان

  • Carin Hagberg
  • Yefim Bogomolny
  • Clarence Gilmore
  • Valentine Gibson
  • Mark Kaitner
  • Somya Khurana
چکیده

Trials of the King LT trade mark (LT, King Systems, Noblesville, IN) in controlled ventilation of the lungs have shown that it is an effective supraglottic airway device. We designed this study to evaluate the King LT regarding ease of insertion, position within the airway, and anatomic sealing properties during spontaneous ventilation in 50 ASA physical status I-III, Mallampati I-III, adult patients undergoing routine general anesthesia. Anesthesia was induced with up to 2 microg/kg fentanyl and 1.5-2 mg/kg propofol and maintained with 70% N2O/30%O2 and isoflurane. Insertion time, oropharyngeal leak pressures, fiberoptic position, and spirometry and hemodynamic data were recorded. Any complications were noted. Insertion was determined to be easy and a patent airway was achieved in all patients. First, second, and third attempt insertion rates were 86%, 12%, and 2%, respectively. Time to place the King LT trade mark was <5 s in 90% of cases. Baseline leak pressures were 31 +/- 8.8 cm H2O (17-50 cm H2O). Complications included laryngospasm (1) and coughing (3) on extubation. The incidence of sore throat at 1 h and 24 h postoperatively was 22% and 15%, respectively. The King LT trade mark is a simple and reliable supraglottic airway device for airway management during spontaneous ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

A Comparison of Midazolam and Mini-Dose Succinylcholine to Aid Laryngeal Mask Airway Insertion During Propofol Anaesthesia

The laryngeal mask airway (LMA) is an ingenious supraglottic airway device that is designed to provide and maintain a seal around the laryngeal inlet for spontaneous ventilation and allow controlled ventilation at modest level of positive pressure [1]. Successful insertion of LMA requires sufficient depth of anaesthesia and depression of airway reflexes to avoid gagging, coughing and laryngeal ...

متن کامل

The optimum sevoflurane concentration for supraglottic airway device Blockbuster™ insertion with spontaneous breathing in obese patients: a prospective observational study

BACKGROUND Airway management of the obese patient presenting for surgery is more likely to be a challenging problem. Supraglottic airway device has been adopted as a bridge to connect ventilation and tracheal intubation in obese patients who would be suffered with difficult intubation. The optimum sevoflurane concentration for supraglottic airway device insertion allowing spontaneous breathing ...

متن کامل

A Comparison of Three Different Supraglottic Airway Devices in Neonatal Airway Training during Resuscitation Simulation

Objective: The aim of this study was to compare the success rates for insertion using the laryngeal mask, laryngeal tube, and I-gel supraglottic airway devices in a neonatal airway manikin during a resuscitation simulation course. Methods: Three groups of health care professionals were given a brief supervised training in using the devices. For each participant the positioning of each device wa...

متن کامل

An evaluation of the Laryngeal Tube during general anesthesia using mechanical ventilation.

UNLABELLED The Laryngeal Tube is a new supraglottic ventilatory device for airway management. It has been developed to secure a patent airway during either spontaneous or mechanical ventilation. In this study, we sought to determine the effectiveness of the Laryngeal Tube for primary airway management during routine surgery with mechanical ventilation. One-hundred-seventy-five subjects classifi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 102 2  شماره 

صفحات  -

تاریخ انتشار 2006