Passive monitoring of the equilibrium factor inside a radon exposure chamber using bare LR 115 SSNTDs
نویسندگان
چکیده
In this paper, we propose and study a method using bare LR 115 SSNTDs for passive monitoring of the equilibrium factor F inside a radon exposure chamber. The method is based on the proxy equilibrium factor Fp which is defined as Fp 1⁄4 r=ðriC0tÞ 1, where ri is the partial sensitivity (i.e., the number of tracks per unit area per unit exposure), C0 is the radon gas concentration and t is the exposure time. Fp was found to be well correlated with F. LR 115 detectors were exposed in a huge exposure chamber with a volume of 43m , with integrated radon exposure and equilibrium factor as 100 kBqm 3 h and 0.680, respectively. The relationship between ri (m) and the removed active layer thickness x (mm) has been determined as ri 1⁄4 0:0041þ 0:0011x. The method has also been verified through determination of the equilibrium factor from the track densities on the LR 115 detectors. The mean of the mid points of the determined ranges of F for a few LR 115 SSNTDs can give a very good estimate of the true equilibrium factor. r 2006 Elsevier B.V. All rights reserved.
منابع مشابه
Sensitivity of LR 115 SSNTD in a diffusion chamber
Solid-state nuclear track detectors (SSNTDs), such as LR 115, have been commonly used in diffusion chambers for long-term measurements of radon gas concentrations. For the LR 115 SSNTD, it has been found that the active layer removed during chemical etching is significantly affected by the presence and amount of stirring, and thus cannot be controlled easily. However, the sensitivity of the LR ...
متن کاملCalibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD
Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...
متن کاملLong-term determination of airborne radon progeny concentrations using LR 115 detectors and the effects of thoron.
The 'proxy equilibrium factor' (F(p)) method has been developed for long-term determination of airborne radon progeny concentrations using LR 115 solid-state nuclear track detectors. In this paper, the effects of (220)Rn on the F(p) method have been studied. The correction to the track density was related to a parameter α which was the ratio of the sum of activity concentrations of alpha-partic...
متن کاملComparative Measurements of Radon Concentration in Soil Using Passive and Active Methods in High Level Natural Radiation Area (HLNRA) of Ramsar
Background: Radon and its daughters are amongst the most important sources of natural exposure in the world. Soil is one of the significant sources of radon/thoron due to both radium and thorium so that the emanated thoron from it may cause increased uncertainties in radon measurements. Recently, a diffusion chamber has been designed and optimized for passive discriminative measurements of rado...
متن کاملNuclear Track Detectors
Approximately half of the human exposure to radiation is due to indoor airborne shortlived progeny (decay products) of the radon gas (Rn). To measure the airborne concentrations of radon gas and/or its progeny, Nuclear Track Detectors (NTDs) are usually employed. The NTDs register the alpha particles emitted by radon gas and its progeny in the form of tracks in the NTDs, which will become visib...