Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board
نویسندگان
چکیده
Electromagnetic interference is a concern for people wearing cardiovascular implantable electronic devices (CIEDs). The aim of this study was to assess the electromagnetic compatibility between CIEDs and the magnetic field of a common wireless charging technology. To do so the voltage induced in CIEDs by Qi A13 design magnetic fields were measured and compared with the performance limits set by ISO 14117. In order to carry this out a measuring circuit was developed which can be connected with unipolar or bipolar pacemaker leads. The measuring system was positioned at the four most common implantation sites in a torso phantom filled with physiological saline solution. The phantom was exposed by using Helmholtz coils from 5 µT to 27 µT with 111 kHz sine‑bursts or by using a Qi A13 design wireless charging board (Qi‑A13‑Board) in two operating modes "power transfer" and "pinging". With the Helmholtz coils the lowest magnetic flux density at which the performance limit was exceeded is 11 µT. With the Qi‑A13‑Board in power transfer mode 10.8% and in pinging mode 45.7% (2.2% at 10 cm distance) of the performance limit were reached at maximum. In neither of the scrutinized cases, did the voltage induced by the Qi‑A13‑Board exceed the performance limits.
منابع مشابه
Arrhythmia Management Devices
2799 According to a recent worldwide survey, current rates of de novo pacemaker and implantable cardioverter-defibrillator (ICD) implantation are higher than those of previous years at >700 000 and >200 000 per year, respectively. Parallel to the growth in cardiovascular implantable electronic device (CIED) use, technological advances have led to new sources of electromagnetic radiation. Modern...
متن کاملCardiovascular implantable electronic devices: a review of the dangers and difficulties in MR scanning and attempts to improve safety
An increasing number of patients are being treated with cardiovascular implantable electronic devices (CIEDs), many of which are MR conditional. There is a lack of literature on the safe scanning of MR conditional CIEDs. This review article discusses MR imaging safety in patients with implanted CIEDs. Guidelines on safe use and indications of imaging patients with MR conditional CIEDs are descr...
متن کاملElectromagnetic interference in an implantable loop recorder caused by a portable digital media player.
The implantable loop recorder has been shown to be a cost-effective tool for diagnosis of intermittent cardiovascular symptoms such as syncope and palpitations. Electromagnetic interference in these recorders may be caused by commonly encountered electronic devices such as antitheft electronic surveillance systems and magnetic resonance imaging cameras. In this report, we describe interference ...
متن کاملAbdominal implantable cardioverter-defibrillator placement in a patient requiring bilateral chest radiation therapy
Introduction The prevalence of cancer in the United States in 2012 was 13.7 million. According to the National Cancer Institute, approximately one half of all patients with cancer will receive some sort of radiation therapy (RT) during the course of their treatment. In a recent single-center case series, nearly 1% of patients receiving RT had cardiac implantable electronic devices (CIEDs). We c...
متن کاملInitial Experience of an Anesthesiology-based Service for Perioperative Management of Pacemakers and Implantable Cardioverter Defibrillators.
BACKGROUND Management of cardiovascular implantable electronic devices (CIEDs), including pacemakers and implantable cardioverter defibrillators, for surgical procedures is challenging due to the increasing number of patients with CIEDs and limited availability of trained providers. At the authors' institution, a small group of anesthesiologists were trained to interrogate CIEDs, devise a manag...