Platelet counting by the coulter LH 750, sysmex XE 2100, and advia 120: a comparative analysis using the RBC/platelet ratio reference method.

نویسندگان

  • Linda M Sandhaus
  • Ebenezer S Osei
  • Neeta N Agrawal
  • Chrisine A Dillman
  • Howard J Meyerson
چکیده

We compared the accuracy and precision of the impedance platelet counts generated by the Beckman Coulter LH 750 and the Sysmex XE 2100 and the optical platelet counts produced by the Advia 120 and the Sysmex XE 2100 withflow cytometric reference platelet counts. Samples analyzed had platelet counts less than 150 x 10(3)/microL (150 x 10(9)/L) with a platelet flag or less than 75 x 10(3)/microL (75 x 10(9)/L) on the Sysmex SE 9500. The 105 samples were run sequentially through each analyzer. Anti-CD41 and anti-CD61 monoclonal antibodies were used for flow cytometric determination of the reference platelet count by the RBC/platelet ratio method. The Beckman Coulter and the Sysmex impedance platelet counts showed better correlation with the reference method than the optical platelet counts by the Advia and the Sysmex. At platelet transfusion thresholds of 10 and 20 x 10(3)/microL (10 and 20 x 10(9)/L), the precision of the impedance methods was somewhat better than that of the optical methods. Current methods of optical platelet counting may not be superior to impedance platelet counts for all patient populations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of platelet counting by automated hematologic analyzers in acute leukemia and disseminated intravascular coagulation: potential effects of platelet activation.

Platelet counting in patients with acute leukemia or disseminated intravascular coagulation (DIC) may have a risk for erroneous counts owing to the presence of nonplatelet particles or platelet activation. We evaluated automated platelet counting methods using the Abbott Cell-Dyn Sapphire (Abbott Diagnostics, Santa Clara, CA), Sysmex XE-2100 (Sysmex, Kobe, Japan), ADVIA 2120 (Siemens Diagnostic...

متن کامل

The Sysmex XN-2000 Hematology Autoanalyzer Provides a Highly Accurate Platelet Count than the Former Sysmex XE-2100 System Based on Comparison with the CD41/CD61 Immunoplatelet Reference Method of Flow Cytometry

Dear Editor The recently launched hematology autoanalyzer Sysmex XN2000 (Sysmex, Kobe, Japan) provides a new method (PLT-F method) for platelet counting based on a fluorescent RNA staining dye named oxazine [1, 2]. The main advantage of the XN2000’s PLT-F method over the former instrument XE-2100’s optical method (PLT-O method) is the ability to identify apoptotic white cells and not count them...

متن کامل

Comparison of automated differential blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in normal and pathologic samples.

Reliable automated blood cell characterization and quantification remain challenging in pathologic samples, whereas slide reviews due to unnecessary flagging should be avoided. We compared 4 modern hematology analyzers-Abbott Sapphire, Siemens Advia 120, Sysmex XE-2100, and Beckman Coulter DxH 800-regarding complete blood cell count (CBC), leukocyte differential count, and flagging efficacy in ...

متن کامل

Accuracy of platelet counting haematology analysers in severe thrombocytopenia and potential impact on platelet transfusion.

Although haematology analysers provide reliable full blood counts, they are known to be inaccurate at enumerating platelets in severe thrombocytopenia. If the thresholds for platelet transfusion, currently set at 10 x 10(9)/l, are to be further reduced, it is vital that the limitations of current analysers are fully understood. The aim of this large multicentre study was to determine the accura...

متن کامل

Is automated platelet counting still a problem in thrombocytopenic blood?

CONTEXT Reliable platelet counting is crucial for indicating prophylactic platelet transfusion in thrombocytopenic patients. OBJECTIVE To evaluate the precision and accuracy of platelet counting for thrombocytopenic patients, using four different automated counters in comparison with the Brecher & Cronkite reference method recommended by the International Committee for Standardization in Hema...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 118 2  شماره 

صفحات  -

تاریخ انتشار 2002