How do reference montage and electrodes setup affect the measured scalp EEG potentials?

نویسندگان

  • Shiang Hu
  • Yongxiu Lai
  • Pedro Antonio Valdés-Sosa
  • Maria Luisa Brings-Vega
  • Dezhong Yao
چکیده

OBJECTIVE Human scalp electroencephalogram (EEG) is widely applied in cognitive neuroscience and clinical studies due to its non-invasiveness and ultra-high time resolution. However, the representativeness of the measured EEG potentials for the underneath neural activities is still a problem under debate. This study aims to investigate systematically how both reference montage and electrodes setup affect the accuracy of EEG potentials. APPROACH First, the standard EEG potentials are generated by the forward calculation with a single dipole in the neural source space, for eleven channel numbers (10, 16, 21, 32, 64, 85, 96, 128, 129, 257, 335). Here, the reference is the ideal infinity implicitly determined by forward theory. Then, the standard EEG potentials are transformed to recordings with different references including five mono-polar references (Left earlobe, Fz, Pz, Oz, Cz), and three re-references (linked mastoids (LM), average reference (AR) and reference electrode standardization technique (REST)). Finally, the relative errors between the standard EEG potentials and the transformed ones are evaluated in terms of channel number, scalp regions, electrodes layout, dipole source position and orientation, as well as sensor noise and head model. MAIN RESULTS Mono-polar reference recordings are usually of large distortions; thus, a re-reference after online mono-polar recording should be adopted in general to mitigate this effect. Among the three re-references, REST is generally superior to AR for all factors compared, and LM performs worst. REST is insensitive to head model perturbation. AR is subject to electrodes coverage and dipole orientation but no close relation with channel number. SIGNIFICANCE These results indicate that REST would be the first choice of re-reference and AR may be an alternative option for high level sensor noise case. Our findings may provide the helpful suggestions on how to obtain the EEG potentials as accurately as possible for cognitive neuroscientists and clinicians.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimating a neutral reference for electroencephalographic recordings: the importance of using a high-density montage and a realistic head model

OBJECTIVE In electroencephalography (EEG) measurements, the signal of each recording electrode is contrasted with a reference electrode or a combination of electrodes. The estimation of a neutral reference is a long-standing issue in EEG data analysis, which has motivated the proposal of different re-referencing methods, among which linked-mastoid re-referencing (LMR), average re-referencing (A...

متن کامل

EEG deblurring techniques in a clinical context.

OBJECTIVES EEG scalp potential distributions recorded in humans are affected by low spatial resolution and by the dependence on the electrical reference used. High resolution EEG technologies are available to drastically increase the spatial resolution of the raw EEG. Such technologies include the computation of surface Laplacian (SL) of the recorded potentials, as well as the use of realistic ...

متن کامل

EEG Instrumentation, Montage, Polarity, and Localization

The source of the EEG potentials recorded from the scalp is the excitatory and inhibitory postsynaptic potentials of pyramidal neurons. Each pyramidal neuron has an apical dendrite and multiple basal dendrites (Fig. 2.1). Excitation of the postsynaptic membrane at the apical dendrite leads to depolarization with an intracellular shift of positive ions (Na). Subsequently the extracellular space ...

متن کامل

Spatial and temporal resolutions of EEG: Is it really black and white? A scalp current density view

Among the different brain imaging techniques, electroencephalography (EEG) is classically considered as having an excellent temporal resolution, but a poor spatial one. Here, we argue that the actual temporal resolution of conventional (scalp potentials) EEG is overestimated, and that volume conduction, the main cause of the poor spatial resolution of EEG, also distorts the recovered time cours...

متن کامل

EEG Recorded from the Ear: Characterizing the Ear-EEG Method

Highlights Auditory middle and late latency responses can be recorded reliably from ear-EEG.For sources close to the ear, ear-EEG has the same signal-to-noise-ratio as scalp.Ear-EEG is an excellent match for power spectrum-based analysis. A method for measuring electroencephalograms (EEG) from the outer ear, so-called ear-EEG, has recently been proposed. The method could potentially enable robu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neural engineering

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2017