Double peacock eye optical element for extended focal depth imaging with ophthalmic applications.

نویسندگان

  • Lenny A Romero
  • María S Millán
  • Zbigniew Jaroszewicz
  • Andrzej Kolodziejczyk
چکیده

The aged human eye is commonly affected by presbyopia, and therefore, it gradually loses its capability to form images of objects placed at different distances. Extended depth of focus (EDOF) imaging elements can overcome this inability, despite the introduction of a certain amount of aberration. This paper evaluates the EDOF imaging performance of the so-called peacock eye phase diffractive element, which focuses an incident plane wave into a segment of the optical axis and explores the element's potential use for ophthalmic presbyopia compensation optics. Two designs of the element are analyzed: the single peacock eye, which produces one focal segment along the axis, and the double peacock eye, which is a spatially multiplexed element that produces two focal segments with partial overlapping along the axis. The performances of the peacock eye elements are compared with those of multifocal lenses through numerical simulations as well as optical experiments in the image space. The results demonstrate that the peacock eye elements form sharper images along the focal segment than the multifocal lenses and, therefore, are more suitable for presbyopia compensation. The extreme points of the depth of field in the object space, which represent the remote and the near object points, have been experimentally obtained for both the single and the double peacock eye optical elements. The double peacock eye element has better imaging quality for relatively short and intermediate distances than the single peacock eye, whereas the latter seems better for far distance vision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal and choroidal findings in oxalate retinopathy using EDI-OCT.

A 55-year-old woman with extensive retinal crystalline deposition secondary to primary hyperoxaluria presented with bilateral loss of vision secondary to oxalate retinopathy. Enhanced depth imaging optical coherence tomography revealed intraretinal, subretinal, and intraretinal and subretinal pigment epithelium, and choroidal focal hyperreflective structures consistent with both neurosensory an...

متن کامل

Spectrally encoded extended source optical coherence tomography.

We have developed an extended source optical coherence tomography (SEES-OCT) technique in an attempt to improve signal strength for ophthalmic imaging. A line illumination with a visual angle of 7.9 mrad is produced by introducing a dispersive element in the infinity space of the sample arm. The maximum permissible exposure (MPE) of such an extended source is 3.1 times larger than that of a "st...

متن کامل

Pulse-encoded ultrasound imaging of the vitreous with an annular array.

The vitreous body is nearly transparent both optically and ultrasonically. Conventional 10- to 12-MHz diagnostic ultrasound can detect vitreous inhomogeneities at high gain settings, but has limited resolution and sensitivity, especially outside the fixed focal zone near the retina. To improve visualization of faint intravitreal fluid/gel interfaces, the authors fabricated a spherically curved ...

متن کامل

Polarization sensitive optical coherence tomography in the human eye

Optical coherence tomography (OCT) has become a well established imaging tool in ophthalmology. The unprecedented depth resolution that is provided by this technique yields valuable information on different ocular tissues ranging from the anterior to the posterior eye segment. Polarization sensitive OCT (PS-OCT) extends the concept of OCT and utilizes the information that is carried by polarize...

متن کامل

Real time modulable multifocality through annular optical elements.

We present and analyze new multifocal optical elements based on an annular distribution of the transmittance. These elements provide selectable number of foci and can be designed to work between two fixed positions or even to provide extended focal depth. The energy of the foci can be modulated through a single parameter that controls the area of each ring. In our study we analyze the quality o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2012