Vibration Control of Structures with Initially Accelerated Passive Tuned Mass Dampers under Near-Fault Earthquake Excitation
نویسندگان
چکیده
This article deals with the applicability of passive tuned mass damper (PTMD) for reducing the dynamic responses of structures under near-fault earthquake excitations. Three types of pulse-like time functions are employed to simulate the near-fault ground motion. The vibration control effectiveness of PTMDs is extensively investigated through the comparisons of response spectrum and response time histories of a structure with and without PTMDs. To suppress structural peak responses, an initial velocity is applied to the PTMD to accelerate its motion. Numerical studies show that the more cycles of a pulse are contained in the ground motion, the more useful a PTMD becomes in reducing the peak structural responses.
منابع مشابه
Performance Evaluation of Viscoelastic and Friction Passive Damping System in Steel Structures
Additional dampers are employed in order to decrease the dynamic response of structure against the earthquake and wind loading recently. In this study, two types of systems related to waste of inactive energy, i.e. frictional damper which is categorized in dampers dependent on movement and viscoelastic damper which is categorized in dampers dependent on velocity, in making steel structures resi...
متن کاملWavelet PSO-Based LQR Algorithm for Optimal Structural Control Using Active Tuned Mass Dampers
This study presents a new method to find the optimal control forces for active tuned mass damper. The method uses three algorithms: discrete wavelet transform (DWT), particle swarm optimization (PSO), and linear quadratic regulator (LQR). DWT is used to obtain the local energy distribution of the motivation over the frequency bands. PSO is used to determine the gain matrices through the online ...
متن کاملEvaluation of TLD Performance in Reducing the Seismic Response of Structures
Tuned Liquid Dampers (TLD) are among passive control devices that have been used to suppress the vibration of structures in recent years. These structures must be adequately presentable as an equivalent single degree of freedom system with long fundamental period. The TLD, located at the top floors of the structure, can dissipate the external input energy into the system through the sloshing ef...
متن کاملEvaluation of TLD Performance in Reducing the Seismic Response of Structures
Tuned Liquid Dampers (TLD) are among passive control devices that have been used to suppress the vibration of structures in recent years. These structures must be adequately presentable as an equivalent single degree of freedom system with long fundamental period. The TLD, located at the top floors of the structure, can dissipate the external input energy into the system through the sloshing ef...
متن کاملOPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS
This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonli...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Comp.-Aided Civil and Infrastruct. Engineering
دوره 25 شماره
صفحات -
تاریخ انتشار 2010