Comparison of dual to single contrast bolus magnetic resonance myocardial perfusion imaging for detection of significant coronary artery disease.

نویسندگان

  • Jan G J Groothuis
  • Frans P P J Kremers
  • Aernout M Beek
  • Stijn L Brinckman
  • Alvin C Tuinenburg
  • Michael Jerosch-Herold
  • Albert C van Rossum
  • Mark B M Hofman
چکیده

PURPOSE To investigate the incremental diagnostic value of dual-bolus over single-contrast-bolus first pass magnetic resonance myocardial perfusion imaging (MR-MPI) for detection of significant coronary artery disease (CAD). MATERIALS AND METHODS Patients (n = 49) with suspected CAD underwent first pass adenosine stress and rest MR-MPI and invasive coronary angiography (CA). Gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) was injected with a prebolus (1 mL) and a large bolus (0.1 mmol/kg). For the single-bolus technique, the arterial input function (AIF) was obtained from the large-contrast bolus. For the dual-bolus technique, the AIF was reconstructed from the prebolus. Absolute myocardial perfusion was calculated by Fermi-model constrained deconvolution. Receiver operating characteristic (ROC) analysis was used to investigate diagnostic accuracy of MR myocardial perfusion imaging for detection of significant CAD on CA at vessel-based analysis. RESULTS The area under the curve (AUC) of the minimal stress perfusion value for the detection of significant CAD using the single-bolus and dual-bolus technique was 0.85 +/- 0.04 (95% confidence interval [CI], 0.77-0.93) and 0.77 +/- 0.05 (95% CI, 0.67-0.86), respectively. CONCLUSION In this study the dual-bolus technique had no incremental diagnostic value over single-bolus technique for detection of significant CAD with the used contrast concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: comparison to single-bolus injection method.

PURPOSE To compare the dual-bolus to single-bolus quantitative first-pass magnetic resonance myocardial perfusion imaging for estimation of absolute myocardial blood flow (MBF). MATERIALS AND METHODS Dogs had local hyperemia of MBF in the left anterior descending (LAD) coronary artery (intracoronary adenosine). Animals (n = 6) had sequential single- and dual-bolus perfusion studies with micro...

متن کامل

Comparison of single to dual bolus MR myocardial perfusion imaging for detection of coronary artery disease

Introduction Absolute myocardial perfusion can be determined using first pass MR myocardial perfusion imaging with a Fermi-model constrained deconvolution [1]. In the analysis, a linear relationship between contrast concentration and signal intensity is mostly assumed. However, at high contrast concentration saturation effects cause a non linear effect. As low contrast concentrations limits the...

متن کامل

Quantitative Myocardial Perfusion Using Conventional Single-Bolus Contrast Imaging Overestimates Absolute Myocardial Blood Flow Compared with Dual-Bolus or Dual-Sequence Cardiac MR Methods

Introduction: Estimates of myocardial blood flow (MBF) from first-pass contrast-enhanced cardiac magnetic resonance (CMR) imaging require accurate measurement of the arterial input function (AIF) from the left-ventricular (LV) blood pool. Both dual-bolus [1] and dual-sequence [2,3] CMR methods have been proposed to maintain the linearity of the LV signal during the contrast passage. Several stu...

متن کامل

Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction

Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 2010