Radiologic assessment of a self-shield with boron-containing water for a compact medical cyclotron
نویسندگان
چکیده
The cyclotron at our hospital has a self-shield of boron-containing water. The amount of induced radioactivity in the boron-containing water shield of a compact medical cyclotron has not yet been reported. In this study, we measured the photon and neutron dose rates outside the self-shield during cyclotron operation. We estimated the induced radioactivities of the boron-containing water used for the self-shield and then measured them. We estimated the activation of concrete outside the self-shield in the cyclotron laboratory. The thermal neutron flux during cyclotron operation was estimated to be 4.72 × 10(2) cm(-2) s(-1), and the activation of concrete in a cyclotron laboratory was about three orders of magnitude lower than the clearance level of RS-G-1.7 (IAEA). The activity concentration of the boron-containing water did not exceed the concentration limit for radioactive isotopes in drainage in Japan and the exemption level for Basic Safety Standards. Consequently, the boron-containing water is treatable as non-radioactive waste. Neutrons were effectively shielded by the self-shield during cyclotron operation.
منابع مشابه
Design and fabrication of high density borated polyethylene nanocomposites as a neutron shield
Background: Polyethylene composites including boron can be used as an effective neutron shield. Our investigation focuses on manufacturing borated polyethylene nano-composite. The purpose of this study is to design a radiation shield for use in both neutron and gamma fields. Materials and Methods: Borated polyethylene shields containing 2%, and 5% weight percentage of Boron nano-particles w...
متن کاملMeasurement of Neutron Flux in a Medical Compact cyclotron room with Boron-Containing water Self-Shielding
a) Department of Radiological Sciences, School of Health Sciences, Ibaraki Prefectural University of Health Sciences, Ami 4669-2, Ami-machi, Inashiki-gun, Ibaraki 300-0394, Japan b) MI clinic, Syouji 1-12-13, Toyonaka City, Osaka 560-0004, Japan c) National Institute of Public Health, Minami 2-3-6, Wako City, Saitama 351-0197, Japan d) Yokohama Rousai Hospital, Kodzukue-cho 3211, Kofuku-ku, Yok...
متن کاملDesign and manufacture of composite flexible shield for neutron-gamma mixed fields
In this study, a flexible composite shield with a combination of polyethylene, tungsten and boron carbide has been designed and constructed for neutron-gamma mixed fields. For this purpose, theoretical studies were conducted using the multi-purpose MCNPX Code. According to the results of simulation studies, a multi-purpose composite was constructed using a combination of a solid phase of boron ...
متن کاملUsing Zirconium Borohydride as Neutron Shield in LINAC head
Introduction: One of the concerns about using of high energy photons in radiotherapy is neutron contamination production. The threshold energy of photoneutron production in most materials with high atomic number is about 7MeV. Therefore, it seems to be logical that the main components with high atomic number elements used in the LINAC head have a large contribution to the neutr...
متن کاملInvestigation of Developed Shield Composition to Neutron Shielding in Treatment Room for BNCT to Reduce Clinical Effects
Background and Aim: One of the best radiotherapy methods that have been suggested for the treatment of cancers such as brain, head and neck, skin, and recently liver is boron neutron capture therapy. Therefore, neutron shielding in the treatment room is important because the absorption of neutrons in the shield may lead to the production of gamma rays, which can have destructive effects. While ...
متن کامل