Preparation of a candidate primary reference material for the international standardisation of HbA1c determinations.
نویسندگان
چکیده
We prepared a candidate primary reference material for the forthcoming international standardisation of beta-N-terminal glycated hemoglobin A measurements. It consists of well-defined mixtures of purified beta-N-terminal glycated hemoglobin A and non-glycated hemoglobin A. First, beta-N-terminal glycated hemoglobin A and non-glycated hemoglobin A were isolated, purified to homogeneity, and characterised. The techniques used were cation exchange and affinity chromatography for the purification, and high performance liquid chromatography, capillary isoelectric focusing, electrospray ionisation mass spectrometry, and peptide mapping for the characterisation. Hemoglobins from blood of healthy, non-diabetic volunteers were obtained with a purity of > 99.5% for non-glycated hemoglobin A and of > 98.5% for beta-N-terminal glycated hemoglobin A. However, results from peptide mapping indicate that the beta-N-terminal glycated hemoglobin A preparations still contain some non-beta-N-terminal glycated hemoglobins, co-eluting with beta-N-terminal glycated hemoglobin A. The exact content of beta-N-terminal glycated hemoglobin A in these preparations could be determined by a procedure consisting of standard addition, enzymatic cleavage and quantification of the resulting beta-N-terminal peptides to be in the range from 95-97.5%. Since the beta-N-terminal glycated hemoglobin A and non-glycated hemoglobin A content could be exactly determined in the materials prepared, mixtures of both components could be successfully used to calibrate the candidate reference methods.
منابع مشابه
HbA1c standardisation destination--global IFCC Standardisation. How, why, where and when--a tortuous pathway from kit manufacturers, via inter-laboratory lyophilized and whole blood comparisons to designated national comparison schemes.
Glycohaemoglobins were first used in routine clinical laboratories for diabetes monitoring around 1977 and at the time all methods had either no calibrators, or used material with assayed values derived from individual manufacturers' assays. Over the next five to fifteen years, lyophilised and whole blood sample exchanges were shown to improve inter-laboratory variability markedly. The use of a...
متن کاملAccuracy, standardization, and interlaboratory calibration standards for foraminiferal Mg/Ca thermometry
[1] The use of liquid and solid standards for foraminiferal Mg/Ca and Sr/Ca determinations and interlaboratory calibration has been investigated. Preparation of single element standard solutions from primary solid standard material enables the preparation of mixed standard solutions with Mg/Ca and Sr/Ca ratios of known accuracy to better than 0.1%. We also investigated commercial reference mate...
متن کاملارزیابی هزینه- اثربخشی روشهای اندازهگیری HbA1C در ایران
Background: Diabetic patients need to be followed for glycemic index regularly and HbA1c test is one of the most important biochemical markers for patient monitoring. HbA1c should be standardized based on international standards, but using internationally accepted assays are expensive. This study aimed to evaluate cost effectiveness of different assays which are currently used in Iran. ...
متن کاملElimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملEvaluation of Accuracy, Precision and Agreement of Five Hba1c Measurement Methods with HPLC Reference Method
ABSTRACT Background and Objective: The current challenge of diabetes mellitus is to prevent its complications. These complications are directly associated with hyperglycemia in diabetics. The HbA1c measurement is essential for long-term glycemic control. Synchronization of HbA1c measurement is important in order to avoid discrepancies between resu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 36 5 شماره
صفحات -
تاریخ انتشار 1998