Effects of scatter correction on regional distribution of cerebral blood flow using I-123-IMP and SPECT.

نویسندگان

  • H Ito
  • H Iida
  • T Kinoshita
  • J Hatazawa
  • T Okudera
  • K Uemura
چکیده

The transmission dependent convolution subtraction method which is one of the methods for scatter correction of SPECT was applied to the assessment of CBF using SPECT and I-123-IMP. The effects of scatter correction on regional distribution of CBF were evaluated on a pixel by pixel basis by means of an anatomic standardization technique. SPECT scan was performed on six healthy men. Image reconstruction was carried out with and without the scatter correction. All reconstructed images were globally normalized for the radioactivity of each pixel, and transformed into a standard brain anatomy. After anatomic standardization, the average SPECT images were calculated for scatter corrected and uncorrected groups, and these groups were compared on pixel by pixel basis. In the scatter uncorrected group, a significant overestimation of CBF was observed in the deep cerebral white matter, pons, thalamus, putamen, hippocampal region and cingulate gyrus as compared with scatter corrected group. A significant underestimation was observed in all neocortical regions, especially in the occipital and parietal lobes, and the cerebellar cortex. The regional distribution of CBF obtained by scatter corrected SPECT was similar to that obtained by O-15 water PET. The scatter correction is needed for the assessment of CBF using SPECT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A case of intravascular lymphoma with increased regional cerebral blood flow in I-123 IMP single-photon emission CT.

This report documents a case of intravascular lymphoma (IVL) with increased regional cerebral blood flow (rCBF) disclosed at I-123 IMP single-photon emission CT (IMP-SPECT). A 73-year-old woman with IVL had high rCBF disclosed by IMP-SPECT before chemotherapy; rCBF was normal after one course of CHOP (cyclophophamide, vincristine, doxorubicin, and prednisone) chemotherapy. During her clinical c...

متن کامل

Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 labeled water PET and voxel-based morphometry.

OBJECTIVES Three accumulative tracers, iodine-123-labeled N-isopropyl-p-iodoamphetamine (I-123-IMP), technetium-99m-labeled hexamethylpropyleneamineoxime (Tc-99m-HMPAO), and technetium-99m-labeled ethyl cysteinate dimer (Tc-99m-ECD) are widely used to measure cerebral blood flow (CBF) in single-photon emission computed tomography (SPECT). In the present study, normal regional distribution of CB...

متن کامل

Quantitative measurement of regional cerebrovascular reactivity to acetazolamide using 123I-N-isopropyl-p-iodoamphetamine autoradiography with SPECT: validation study using H2 15O with PET.

UNLABELLED A simplified technique using (123)I-N-isopropyl-p-iodoamphetamine ((123)I-IMP) autoradiography (ARG) with SPECT has been proposed recently for quantifying regional cerebral blood flow (rCBF). To validate the accuracy of (123)I-IMP-ARG for quantifying regional cerebrovascular reactivity (rCVR) to acetazolamide, we compared rCVR determined using (123)I-IMP-ARG with that determined usin...

متن کامل

A comparative study of simple methods to measure regional cerebral blood flow using iodine-123-IMP SPECT.

UNLABELLED The aim of this study was to compare the accuracy and reliability of simple methods of quantifying regional cerebral blood flow (rCBF) with 123I-labeled N-isopropyl-p-iodoamphetamine (IMP) and SPECT and to determine which method was best. METHODS Four methods were examined: (a) the microsphere method with continuous withdrawal of arterial blood, which was based on a microsphere mod...

متن کامل

A simple non-invasive I-123-IMP autoradiography method developed by modifying the simple non-invasive I-123-IMP microsphere method

Objective: We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 1999