Enzymic measurement of cholesterol in serum with the CentrifiChem centrifugal analyzer.

نویسندگان

  • M A Pesce
  • S H Bodourian
چکیده

Cholesterol is measured by mixing 5 mul of sample with 350 mul of a reagent consisting of phenol, 4-aminoantipyrine, and the enzymes cholesterol oxidase, cholesterol esterase, and peroxidase. After 12 min, the resulting quinoneimine is measured at 520 nm. Readings and cholesterol concentrations are linearly related up to 4.0 g/liter. Lipemic sera and samples containing uric acid (up to 200 mg/liter), hemoglobin (up to 1 g/liter), and certain drugs (clofibrate, phenobarbital, nicotinic acid, Ketochol, Ovral-28), gave no interference. Abnormally high concentrations of bilirubin and ascorbic acid in serum lowered the cholesterol values. This enzymic assay, compared with the method of Abell and with a rate method that uses the Hantzsch reaction, gave correlation coefficients of 0.987 and 989, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinetic determination of total serum protein with a centrifugal analyzer.

The new generation of centrifugal parallel fast analyzers, such as the “CentrifiChem,” is generally thought of primarily as enzyme analyzers, because of the several attractive characteristics they possess for such assays. With them, one can make an initial reading within several seconds of starting a reaction. They therefore can also be used to determine the concentration of selected compounds,...

متن کامل

Automated reaction-rate method for the direct determination of total serum cholesterol by use of the "CentrifiChem" parallel fast analyzer.

The direct procedure for determining serum cholesterol described by Wybenga et al. [C/in. Chem. 16, 980 (1970)] can be used to assay 29 samples in 10-mm reaction time by using the “CentrifiChem” parallel fast analyzer (Union Carbide). Commercial reference serum was used for standardization. Correlation of results with those obtained by the method of Abell et al. [J. Bio/. Chem. 195, 357 (1952)]...

متن کامل

Kinetic measurement of total amylase and isoamylase activities with a centrifugal analyzer.

We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-starch technique. The method for total amylase appeared to be rapid and precise (C...

متن کامل

Effects of various serum proteins on quantification of fructosamine.

We determined fructosamine concentrations with the CentrifiChem 600 centrifugal analyzer and the Hitachi 737 discrete analyzer. Reference intervals agreed with the most recently published results, and values in fasting patients were significantly correlated with glycated hemoglobin, plasma glucose, albumin, beta- and gamma-globulins, IgG, IgA, IgM, and total protein. Partial correlation analysi...

متن کامل

A bichromatic method for total bilirubin with a CentrifiChem 400.

We describe a method for the bichromatic determination of total bilirubin with a CentrifiChem 400 centrifugal analyzer with the Boehringer DPD kit. After reading the blank at 620 nm, we read the test at 550 nm. Because only one rotor is required, the analytical time for bilirubin estimations is halved. The proposed method is no more prone to interference by hemoglobin or turbidity than a conven...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 2 PT. 1  شماره 

صفحات  -

تاریخ انتشار 1977