Setup for steady state XAS
نویسندگان
چکیده
a) Ecole polytechnique Fédérale de Lausanne, Laboratoire de spectroscopie ultrarapide, ISIC, FSB-BSP, CH-1015 Lausanne, Switzerland b) Ecole polytechnique Fédérale de Lausanne, Laboratoire de chimie et biochimie computationnelles, ISIC, FSBBSP, CH-1015 Lausanne, Switzerland c) Paul Scherrer Institut, CH-5232 Villigen, Switzerland. d) Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare, CP13, 00044 Frascati, Italy.
منابع مشابه
Spin injection and relaxation in ferromagnet-semiconductor heterostructures
We present a detailed description of spin injection and detection in Fe/AlxGa1−xAs/GaAs heterostructures for temperatures from 2 to 295 K. Measurements of the steady-state spin polarization in the semiconductor indicate three temperature regimes for spin transport and relaxation. At temperatures below 70 K, spinpolarized electrons injected into quantum well structures form excitons, and the spi...
متن کاملMobility model for III-V compounds suited for hydrodynamic device simulation
We propose an improved mobility model for hydrodynamic device simulation . The mobility is modeled as function of the total mean energy. Expressions for the individual valley mobilities are combined by means of the relative valley populations estimated by a modified Boltzmann distribution. Our model is based on steady-state Monte Carlo calculations and reflects the situation of intervalley tran...
متن کاملUnreliable Server Mx/G/1 Queue with Loss-delay, Balking and Second Optional Service
This investigation deals with MX/G/1 queueing model with setup, bulk- arrival, loss-delay and balking. The provision of second optional service apart from essential service by an unreliable server is taken into consideration. We assume that the delay customers join the queue when server is busy whereas loss customers depart from the system. After receiving the essential service, the customers m...
متن کاملSimultaneous surface plasmon resonance and x-ray absorption spectroscopy.
We present an experimental setup for the simultaneous measurement of surface plasmon resonance (SPR) and x-ray absorption spectroscopy (XAS) on metallic thin films at a synchrotron beamline. The system allows measuring in situ and in real time the effect of x-ray irradiation on the SPR curves to explore the interaction of x-rays with matter. It is also possible to record XAS spectra while excit...
متن کاملAnalysis of Setup Energy of LEACH Protocol for Wireless Sensor Networks
In Wireless Sensor Network (WSN) the sensor nodes are very much sensitive to the energy consumption. The reliable operation can be performed in the network (NW) by using hierarchical protocols for communication of data, which can conserve energy of nodes in network. LEACH is the basic protocol developed for the said purpose, in which the operation of network is performed in two steps, namely Se...
متن کامل