In vivo investigations of accuracy and precision of fiber orientations in crossing fibers in spherical deconvolution-based HARDI methods
نویسندگان
چکیده
Target audience: Researchers interested in optimizing High-Angular Resolution Diffusion Imaging acquisitions. Introduction: Diffusion MRI methods based on high-angular resolution diffusion imaging (HARDI) acquisitions provide a good trade-off between acquisition time and accuracy of the estimated diffusion or fiber orientation distribution function (dODF/fODF) [1-3]. Recently, an extensive evaluation was done on the effect of the number of diffusion-weighting (DW) gradient orientations and the b-value on the accuracy of a spherical harmonics representation of the DW signal of a single fiber population [3]. A b-value of 3000 s/mm was shown to be optimal to describe the angular profile of the signal [3]. Both the maximum spherical harmonic order detected and the accuracy of the fit are strongly dependent on the effective angular SNR (i.e., the SNR and the number of DWIs) and b-value. This work presents an overview of how these factors affect fODF estimation in crossing fiber voxels in vivo, investigating the accuracy and precision of the reconstructed fODF peaks. Specifically, we intend to determine if there are situations were low b-value and a high number of DWIs is equal to or better than a high b-value and a relatively low number of DWIs (e.g., the performance of CSD is at b=1000 s/mm with 200 DWIs equals that at b=3000 s/mm with only 100 DWIs), and what would be optimal in terms of scan time. Methods: Acquisition: a DWI dataset of a 24 year-old healthy subject was acquired on a 3.0 T Philips Achieva, with three shells at b-values of 1000, 2000, and 3000 s/mm with 250 gradient directions in each shell, and 75 b=0 images. The images from the three shells were acquired across different sessions (similar to the repeated sessions in [4]). Acquisition details: matrix 96×96; FOV 240×240; 2.5 mm slices for an isotropic voxel size of 2.5 mm [5]; SENSE=2.5; TE/TR: 100/7500 ms; SNR of b=0 images about 32 in the WM. Test datasets: For all shells, ten subsets were created for sets with the following number of gradient directions: {50, 60, 70, 80, 90, 100, 125, 150, 175, 200, 225}, as described in [6]. fODF estimation: For all subsets, fODFs were estimated using CSD (Lmax 6 or 8) in ExploreDTI, where the response function was estimated recursively [2,7-9]. Analysis: fODF peak orientations were extracted to investigate the accuracy and precision for each combination of b-value, Lmax, and number of gradient directions (Fig. 1). Two voxels were investigated: one voxel with two distinct fiber populations (bottom indicated voxel in Fig. 1a); and one with three (top indicated voxel in Fig. 1a). A “silver standard” peak orientation was obtained for each fiber population from the b=3000 data modeled with Lmax=8 by creating 100 subsets of the 225 directions and averaging the peak orientations over these 100 subsets. For each of the other combinations of b-value, Lmax, and number of directions, mean peaks were obtained in a similar fashion, averaging over the 10 subsets. The mean angular deviation of all these mean peaks was calculated by taking the angle with respect to the corresponding peak from the “silver standard”, as a measure of accuracy. The angular deviation is taken as a measure of precision, and calculated as the standard deviation over peak orientations of the 10 subsets per setting. Results: Example fODFs for a two-fiber voxel are shown in Fig. 1 for different b-values and Lmax settings. Fig. 2 shows the mean angular difference and the angular deviation for each set of parameters. For all the fODF peaks and settings investigated, the mean angular difference reaches a stable value with increasing number of gradient directions. In terms of accuracy, the increase in effective angular resolution with b-value means that less gradient directions are required to reach this high accuracy. The angular deviation (Fig. 2c,f) is very stable and very low, indicating a very good precision for all used b-values and Lmax values for ≥100 directions. Discussion: Confirming the single-fiber voxels results from [3], higher b-values provide high levels of precision and accuracy, even for relatively low number of gradient orientations (50-100). On the whole, more DWIs at lower b-values performed to a similar level of precision as high b-values with fewer DWIs. At standard clinical 3 T MR systems, higher b-values require longer DW gradients, increasing TE and thus TR. At a 2.5 mm resolution, this increase in TE is roughly 10 ms to increase the b-value from 1000 to 2000 and another 10 ms for b=3000 (at GMAX 30-40 mT/m). This results in an increase in TR of roughly 8 and 16% from b=1000 to b=2000 and b=3000, respectively. For any given accuracy (Fig. 2), increasing the b-value is more scan-time-efficient than increasing the number of DWIs. Future work will focus on 1) investigating the effect of TE prolongation at higher b-values on the SNR, and 2) varying the SNR to determine if these results generalize to more imaging settings, e.g., higher spatial resolutions where the SNR is typically lower. References: [1] Tuch, MRM 2004;52:1358-72; [2] Tournier et al., NeuroImage 2007;35:1459-72; [3] Tournier et al., NMR Biomed 2013, in press; [4] Jeurissen et al., HBM 2012, in press; [5] Vos et al., ISMRM 2011 p1945; [6] Vos et al., ISMRM 2013 p842; [7] Leemans et al., ISMRM 2009 p3536; [8] Jeurissen et al., HBM 2011;32:461-79; [9] Tax et al., NeuroImage 2013, in press. Fig. 1: The two voxels investigated are shown in a) by the green boxes. b)-e) show fODFs for one subsets with 100 gradient directions (the bottom indicated voxel), from datasets with different bvalues and Lmax values (as denoted in the figure).
منابع مشابه
Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter
Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...
متن کاملA Modified Damped Richardson-Lucy Algorithm to Improve the Estimation of Fiber Orientations in Spherical Deconvolution
Introduction:. Standard spherical deconvolution approaches assume that HARDI signal can be modeled as a convolution between a common fiber response and a fiber orientation distribution function [1][2]. Recent spherical deconvolution methods improved the quality of the results introducing the non negative constraint of the solution [3][4][5]. It can be verified, however, that instability problem...
متن کاملSparse Solution of Fiber Orientation Distribution Function by Diffusion Decomposition
Fiber orientation is the key information in diffusion tractography. Several deconvolution methods have been proposed to obtain fiber orientations by estimating a fiber orientation distribution function (ODF). However, the L 2 regularization used in deconvolution often leads to false fibers that compromise the specificity of the results. To address this problem, we propose a method called diffus...
متن کاملProbabilistic fiber tracking using the residual bootstrap with constrained spherical deconvolution.
Constrained spherical deconvolution (CSD) is a new technique that, based on high-angular resolution diffusion imaging (HARDI) MR data, estimates the orientation of multiple intravoxel fiber populations within regions of complex white matter architecture, thereby overcoming the limitations of the widely used diffusion tensor imaging (DTI) technique. One of its main applications is fiber tractogr...
متن کاملSpherical wavelet transform for ODF sharpening
The choice of local HARDI reconstruction technique is crucial for discerning multiple fiber orientations, which is itself of substantial importance for tractography, and reliable and accurate assessment of white matter fiber geometry. Due to the complexity of the diffusion process and its milieu, distinct diffusion compartments can have different frequency signatures, making the HARDI signal sp...
متن کاملWhite matter structure assessment from reduced HARDI data using low-rank polynomial approximations.
Assessing white matter fiber orientations directly from DWI measurements in single-shell HARDI has many advantages. One of these advantages is the ability to model multiple fibers using fewer parameters than are required to describe an ODF and, thus, reduce the number of DW samples needed for the reconstruction. However, fitting a model directly to the data using Gaussian mixture, for instance,...
متن کامل