Choosing a negative pressure ventilation pump: are there any important differences?

نویسندگان

  • I E Smith
  • M A King
  • J M Shneerson
چکیده

Five negative pressure ventilator pumps were assessed to determine whether there were any differences in performance which were likely to be of clinical importance. The pumps tested were the NEV-100 (Lifecare Inc.), the Negavent Respirator DA-1 (Dima Italia), the Thompson Maxivent (Puritan Bennett), the CCP-001 and Newmarket pumps (Si-Plan Electronics Research Ltd). A patient model was employed to investigate the relationship between the pressure waveform of each pump and the tidal volume generated, the stability of performance on a continuous 8 h test, and the response to a change in leak. On the continuous tests, the stability was better than +/- 1% for the inspiratory/expiratory (I:E) ratio and rate, and better than +/- 10% for the peak negative pressure for all of the pumps. The Negavent and NEV-100 pumps generated a square wave of pressure and for the same peak negative pressure produced a tidal volume up to 30% greater than the CCP-001 and the Newmarket pumps, which produced a half sine wave. The Maxivent produced an intermediate waveform, with a plateau at peak negative pressure but a curved decay back to atmospheric pressure. It is argued that if the pressure of the pumps producing a half sine wave is made more negative to compensate and produce an equivalent tidal volume, they are more likely to induce upper airway obstruction. The leak compensation of the NEV-100 and Negavent pumps was nearly complete but took several breaths to develop, the CCP-001 and Newmarket pumps had a very rapid compensation but this was less complete, whilst the Maxivent has no mechanism for leak compensation. From these results, it seems that in patients liable to upper airway obstruction the NEV-100 and Negavent pumps would be advantageous, whilst when rapidly changing leaks impair the efficiency of negative pressure ventilation the CCP-001 and Newmarket pumps would be preferable. The Maxivent pump seems to offer no advantages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Newmarket pump: a new suction pump for external negative pressure ventilation.

A new electronically controlled pump has been developed for use with a cuirass in providing external negative pressure ventilation. It is smaller, lighter, and more versatile than currently available pumps and operates on a servo principle. A rotary valve between the pump and the cuirass varies the rate of extraction of air from the cuirass. The pressure within the cuirass is sensed by a pressu...

متن کامل

Noninvasive ventilation in chronic ventilatory failure due to chronic obstructive pulmonary disease.

Noninvasive ventilation (NIV) has been one of the major advances in respiratory medicine in the last decade. In particular, it has found widespread application in the management of patients with chronic obstructive pulmonary disease (COPD). There is a robust evidence base for its use in acute exacerbations of COPD, but the evidence that it is effective in chronic COPD is much less strong. Despi...

متن کامل

Intra-aortic balloon pump combined with mechanical ventilation for treating patients aged > 60 years in cardiogenic shock: Retrospective analysis

OBJECTIVE To examine if mechanical ventilation with positive end-expiratory pressure (PEEP) combined with intra-aortic balloon pump (IABP) provided a better outcome than IABP alone for the treatment of cardiogenic shock after acute myocardial infarction in patients aged > 60 years. METHODS This was a retrospective analysis of data from patients in cardiogenic shock, refractory to pharmacologi...

متن کامل

Performance of a Two-stages Gas Gun: Experimental, Analytical and Numerical Analysis

Two stages gas guns are used for various purposes, particularly for mechanical characterization of materials at high rate of deformations. The performance of a two stages gas gun is studied in this work using the theory of the two-stage gas gun proposed by Rajesh, numerical simulation using combined Eulerian/ Lagrangian elements in Autodyna commercial code and experiment using a two stage gas g...

متن کامل

Demand and continuous flow intermittent mandatory ventilation systems.

A mechanical lung was used to evaluate the pressure and flow characteristics of four demand and two continuous flow intermittent mandatory ventilation (IMV) systems. The amount of negative pressure required to initiate inspiratory flow and peak expiratory resistance were measured. The inspiratory pressure required to initiate flow in the demand mode was also compared to pressures generated in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 8 10  شماره 

صفحات  -

تاریخ انتشار 1995