17-hydroxyprogesterone quantification in dried blood spots by high performance liquid chromatography-tandem mass spectroscopy

نویسندگان

  • Kate Waller
  • Michael Henman
  • Tony Huynh
  • Janet Warner
چکیده

Measurement of 17-hydroxyprogesterone (17-OHP) in daily dried blood spot profiles via radioimmunoassay is a convenient and accepted method for monitoring of glucocorticoid therapy in Congenital Adrenal Hyperplasia. Characteristics of this method that serve to limit its clinical usefulness include its lack of specificity for 17-OHP, and a relatively high limit of detection. Mass Spectroscopy is the gold standard method for steroid quantification. We aim to establish a High Performance Liquid Chromatography-Tandem Mass Spectroscopy (HPLC-MS/MS) method for dried blood spot 17-OHP quantification and develop normative ageand tannerspecific, as well as Congenital Adrenal Hyperplasia genotype-phenotype correlated reference ranges to guide glucocorticoid therapy. Four 3mm blood spots were punched from patient dried blood spot filter paper specimens. 17-OHP was eluted into solvent and concentrated using liquid nitrogen. Steroids were separated using high performance liquid chromatography and quantitated by Tandem Mass Spectrometry. For the radioimmunassay/HPLCMS/MS correlations, measurements were performed by both methods on 49 samples from children with glucocorticoid-dependent Congenital Adrenal Hyperplasia, as well as children undergoing dynamic endocrine function testing at The Mater Children’s Hospital. Reference samples for HPLC-MS/MS calibration, and determination of sensitivity, precision, and recovery were prepared using whole blood samples spiked with 17-OHP spotted onto filter paper. Concentrations were expressed as mean (nmol/L), standard deviation, and coefficient of variation (%). There was excellent correlation between HPLC-MS/ MS and radioimmunoassay methods (r=0.9610). For the radioimmunoassay method, the lower limit of quantification has been established at <5 nmol/L while LC-MS/MS allows detection to 1.0 nmol/L (1.2nmol/L, 0.26, 22%) with a proposed lower limit of quantification of 1.5 nmol/L (1.3 nmol/L, 1.3, 13%). We have established an accurate, reliable, and specific method for quantifying 17-OHP concentrations from dried blood spot using HPLC-MS/MS. This will allow for the establishment of clinically relevant and time-specific reference ranges to guide glucocorticoid dose adjustment in children with Congenital Adrenal Hyperplasia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved specificity of newborn screening for congenital adrenal hyperplasia by second-tier steroid profiling using tandem mass spectrometry.

BACKGROUND Newborn screening for congenital adrenal hyperplasia (CAH) involves measurement of 17alpha-hydroxyprogesterone (17-OHP), usually by immunoassay. Because this testing has been characterized by high false-positive rates, we developed a steroid profiling method that uses liquid chromatography-tandem mass spectrometry (LC-MS/MS) to measure 17-OHP, androstenedione, and cortisol simultaneo...

متن کامل

Multiplex Assay of Second-Line Anti-Tuberculosis Drugs in Dried Blood Spots Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry

As dried blood spots (DBSs) have various advantages over conventional venous blood sampling, some assays for detection of one or two anti-tuberculosis (TB) drugs in DBSs have been developed. However, there are no assays currently available for the simultaneous measurement of three or more anti-TB drugs in DBSs. In this study, we developed and evaluated a multiplex method for detecting nine anti...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Quantification of Warfarin in Dried Rat Plasma Spots by High-Performance Liquid Chromatography with Tandem Mass Spectrometry

This paper presents the development and validation of a novel method for quantification of the oral anticoagulant drug warfarin in dried plasma spots (DPS) by high-performance liquid chromatography with tandem mass spectrometry (HPLC-MS/MS). Blood plasma was chosen as a biological fluid to preclude the influence of the hematocrit on the results of the analysis. A 30 μL sample of rat plasma was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015