MR imaging of large multinodular goiters: observer agreement on volume versus observer disagreement on dimensions of the involved trachea.

نویسندگان

  • Steen J Bonnema
  • Peter B Andersen
  • Dorthe U Knudsen
  • Laszlo Hegedüs
چکیده

OBJECTIVE MR imaging and sonography are considered to be among the most reliable methods available for estimating goiter volume. Our aim was to assess the observer variability of MR imaging for estimating the volume of a large multinodular goiter and the dimensions of the related trachea. Additionally, we compared the goiter volume estimates from MR imaging with those from sonography. SUBJECTS AND METHODS The effect of high-dose (131)I therapy on the thyroid gland and the impact on the trachea in 23 patients with a large multinodular goiter (range in volume, 100-703 mL) were monitored by observers unaware of duplicated measurements on MR imaging (n = 68) before, 1 week after, and 1 year after (131)I therapy. In goiters exclusively cervically located (n = 12), cross-sectional planimetric sonographic measurements (n = 24) were performed simultaneously with MR imaging. RESULTS The mean intraobserver difference for the MR imaging measurements of goiter volume was 2.1 mL (1.4%, p = 0.32), and the coefficient of variation (CV) +/- SD was 3.6% +/- 2.6%. The mean interobserver difference was 0.4 mL (0.3%, p = 0.86), and the CV +/- SD was 4.1% +/- 3.5%. Compared with MR imaging, sonography underestimated goiter volume; the mean percentage difference between the volume estimates on MR imaging and those on sonography (volume estimated on MR imaging - volume estimated on sonography) was 19.5% (95% limits of agreement: -22.2% to 83.7%), and the CV +/- SD was 15.0% +/- 12.4%. The mean interobserver difference in the MR imaging measurement of tracheal volume along the goiter extension was 7.4% (95% confidence interval: 4.0-10.8%) and that of the smallest cross-sectional area of the trachea was 7.9% (95% confidence interval: 2.9-13.2%). The corresponding CV +/- SD were 8.1% +/- 6.6% and 10.3% +/- 10.3%, respectively. CONCLUSION For the estimation of goiter volume, MR imaging has low intra- and interobserver variations. In contrast, the determination of tracheal dimensions using MR imaging has a high variability and, thus, is imprecise. Sonography significantly underestimates thyroid volume compared with MR imaging in patients with a large goiter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures

  Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures.   Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...

متن کامل

MRI-Arthroscopic Correlation in Rotator Cuff Tendon Pathologies; A Comparison between Various Centers

    Background: Magnetic resonance imaging (MRI) has long been considered a perfect imaging study for evaluation of shoulder pathologies despite occasional discrepancies between MR reports and arthroscopic findings. In this study we aim to evaluate impact of imaging center as an indicator of image quality on accuracy of MRI reports in diagnosis of rotator cuff tendon pathologies. Methods: We re...

متن کامل

AN OBSERVER-BASED INTELLIGENT DECENTRALIZED VARIABLE STRUCTURE CONTROLLER FOR NONLINEAR NON-CANONICAL NON-AFFINE LARGE SCALE SYSTEMS

In this paper, an observer based fuzzy adaptive controller (FAC) is designed fora class of large scale systems with non-canonical non-affine nonlinear subsystems. It isassumed that functions of the subsystems and the interactions among subsystems areunknown. By constructing a new class of state observer for each follower, the proposedconsensus control method solves the problem of unmeasured sta...

متن کامل

A Variable Structure Observer Based Control Design for a Class of Large scale MIMO Nonlinear Systems

This paper fully discusses how to design an observer based decentralized fuzzy adaptive controller for a class of large scale multivariable non-canonical nonlinear systems with unknown functions of subsystems’ states. On-line tuning mechanisms to adjust both the parameters of the direct adaptive controller and observer that guarantee the ultimately boundedness of both the tracking error and tha...

متن کامل

Comparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography

Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 179 1  شماره 

صفحات  -

تاریخ انتشار 2002