A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy.

نویسندگان

  • M R Arnfield
  • J V Siebers
  • J O Kim
  • Q Wu
  • P J Keall
  • R Mohan
چکیده

The main purpose of this work is to demonstrate a practical means of determining the leaf transmission and scatter characteristics of a multileaf collimator (MLC) pertinent to the commissioning of dynamic intensity modulated radiotherapy, especially for the sweeping window technique. The data are necessary for the conversion of intensity distributions produced by intensity-modulated radiotherapy optimization systems into trajectories of MLC leaves for dynamic delivery. Measurements are described for two, tungsten alloy MLCs: a Mark II 80-leaf MLC on a Varian 2100C accelerator and a Millenium 120-leaf MLC on a Varian 2100EX accelerator. MLC leakage was measured by film for a series of field sizes. Measured MLC leakage was 1.68% for a 10 x 10 cm2 field for both 6 and 18 MV for the 80-leaf MLC. For the 6 MV field, the 1.68% leakage consisted of 1.48% direct transmission and 0.20% leaf scatter. Direct transmission through the 80-leaf MLC, including the rounded leaf tip, was calculated analytically taking into account the detailed leaf geometry and a Monte Carlo-generated energy spectrum of the accelerator. The integrated fluence under the leaf tip was equivalent to an inward shift of 0.06 cm of a hypothetical leaf with a flat, focused tip. Monte Carlo calculations of the dose to phantom beyond a closed 80-leaf MLC showed excellent agreement with the analytic results. The transmission depends on the density of the MLC alloy, which may differ among individual MLCs. Thus, it is important to measure the transmission of any particular MLC. Calculated doses for a series of uniform fields produced by dynamic sweeping windows of various widths agree with measurements within 2%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy.

The use of a multileaf collimator in the dynamic mode to perform intensity modulated radiotherapy became a reality at our institution in 1995. Unlike treatment with static fields using a multileaf collimator, there are significant dosimetric issues which must be assessed before dynamic therapy can be implemented. We have performed a series of calculations and measurements to quantify head scatt...

متن کامل

Design, Simulation and Manufacture of a Multileaf Collimator to Confirm the Target Volumes in Intensity Modulated Radiation Therapy

Introduction: Intensity modulated radiation therapy (IMRT) is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (MLC). Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...

متن کامل

A new mathematical model for intensity matrix decomposition using multileaf collimator

Cancer is one of the major causes of death all over the globe and radiotherapy is considered one of its most effective treatment methods. Designing a radiotherapy treatment plan was done entirely manually in the past. RecentlyIntensity Modulated Radiation Therapy (IMRT) was introduced as a new technology with advanced medical equipmentin the recent years. IMRT provides the opportunity to delive...

متن کامل

Determination of depth and field size dependence of multileaf collimator transmission in intensity‐modulated radiation therapy beams

Intensity-modulated radiation therapy (IMRT) plans for the treatment of large and complex volumes may contain a relatively large contribution from multileaf collimator (MLC) transmission. In such cases, comprehensive characterization of direct and scatter MLC transmission is important. We designed a set of tests (open beam, closed static MLC, and dynamic MLC gap) to determine dosimetric MLC pro...

متن کامل

Dosimetric and qualitative analysis of kinetic properties of millennium 80 multileaf collimator system for dynamic intensity modulated radiotherapy treatments.

The aim of this paper is to analyze the positional accuracy, kinetic properties of the dynamic multileaf collimator (MLC) and dosimetric evaluation of fractional dose delivery for the intensity modulated radiotherapy (IMRT) for step and shoot and sliding window (dynamic) techniques of Varian multileaf collimator millennium 80. Various quality assurance tests such as accuracy in leaf positioning...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 27 10  شماره 

صفحات  -

تاریخ انتشار 2000