Dependence and independence of survival parameters on linear energy transfer in cells and tissues

نویسندگان

  • Koichi Ando
  • Dudley T. Goodhead
چکیده

Carbon-ion radiotherapy has been used to treat more than 9000 cancer patients in the world since 1994. Spreading of the Bragg peak is necessary for carbon-ion radiotherapy, and is designed based on the linear-quadratic model that is commonly used for photon therapy. Our recent analysis using in vitro cell kills and in vivo mouse tissue reaction indicates that radiation quality affects mainly the alpha terms, but much less the beta terms, which raises the question of whether this is true in other biological systems. Survival parameters alpha and beta for 45 in vitro mammalian cell lines were obtained by colony formation after irradiation with carbon ions, fast neutrons and X-rays. Relationships between survival parameters and linear energy transfer (LET) below 100 keV/μm were obtained for 4 mammalian cell lines. Mouse skin reaction and tumor growth delay were measured after fractionated irradiation. The Fe-plot provided survival parameters of the tissue reactions. A clear separation between X-rays and high-LET radiation was observed for alpha values, but not for beta values. Alpha values/terms increased with increasing LET in any cells and tissues studied, while beta did not show a systematic change. We have found a puzzle or contradiction in common interpretations of the linear-quadratic model that causes us to question whether the model is appropriate for interpreting biological effectiveness of high-LET radiation up to 500 keV/μm, probably because of inconsistency in the concept of damage interaction. A repair saturation model proposed here was good enough to fit cell kill efficiency by radiation of wide-ranged LET. A model incorporating damage complexity and repair saturation would be suitable for heavy-ion radiotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams

Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...

متن کامل

Review of Geant4 Applications in Radiobiology

Introduction: Ionizing radiation is widely used in industry and medicine; however, it causes a significant health hazard by making microscopic damage to living tissue. Various biological parameters, including cell survival fraction and relative biological effectiveness, are taken into account to assess the severity and extent of biological damages. Microdosimetry suffe...

متن کامل

Effects of Some Thermo-Physical Parameters on Free Convective Heat and Mass Transfer over Vertical Stretching Surface at Absolute Zero

Effects of some thermo-physical parameters on free convective heat and mass transfer over a vertical stretching surface at lowest level of heat energy in the presence of suction is investigated. The viscosity of the fluid is assumed to vary as a linear function of temperature and thermal conductivity is assumed constant. A similarity transformation is applied to reduce the governing equations i...

متن کامل

Microdosimetry: experimental methods and medical applications

Introduction: Microdosimetry is a fundamental method that studies the nature of energy transfer in micron volumes in the particular biological cells. In a biological target, the amount of ionization does not indicate the magnitude of biological radiation-induced damage. However, the severity of biological harm depends strongly on the amount of the linear energy transfer along t...

متن کامل

Optimum neutron energy simulation in treatment of head and neck cancer at different depths in the BNCT method

Introduction: Recently head and neck cancer has pay attention to many researchers. Its therapeutic methods include surgery, chemotherapy, radiotherapy and Boron neutron capture therapy (BNCT). BNCT is better than conventional radiotherapy because it targets the tumor cell. This method involves two steps of infusion of stable 10B and then neutron radiation with a suitable intens...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 57  شماره 

صفحات  -

تاریخ انتشار 2016