Five-year results of a cementless short-hip-stem prosthesis
نویسندگان
چکیده
Hip prosthesis stems with a short stem length and proximal fixation geometry support a bone-preserving and muscle-sparing implantation and should also allow for revision surgery with a standard hip stem. We present 250 prospectively documented clinical and radiological results from the Metha Short Hip Stem prosthesis (B. Braun-Aesculap, Tuttlingen, Germany) after an average follow-up of 4.9 years. The average patient age at surgery was 60 years. Indication for total hip replacement was primary osteoarthrosis (OA) (78% of patients), OA based on developmental dysplasia of the hip (16%), and other indications (6%). At the last follow-up, the average Harris Hip Score was 97 points. 85% of patients were very satisfied and 14% were satisfied after surgery, whereas 1% were dissatisfied. Pain according to the Visual Analogue Scale improved from 7.4 (min 1.6, max 9.5) pre-operatively to 0.23 (min 0, max 6.6). No joint dislocations occurred when predominantly using 28 mm and 32 mm prosthesis heads. Nine short-stems were revised: three after bacterial infections, two after primary via valsa with penetration of the femoral cortex two and three months after surgery, and three after early aseptic cases of loosening within the first year. A further nine osseously consolidated short-stems had to be replaced due to breakage of the modular titanium cone adapter after an average of 3.1 years (min 1.9, max 4.4). All surgical revisions were performed using primary standard stems. Without taking the material-related adapter failures into account, a five year Kaplan-Meier survival rate of 96.7% (95% confidence interval 93.4-98.3) was determined for the short-stem prostheses. There were no radiological signs of loosening in any of the short-stem prostheses at the last examination. Fine sclerotic lines were detected in Gruen's AP zones 1 (19%) and 2 (10.5%), individual hypertrophies in zone 3 (3.5%), fine seams in zones 4 (5.5%) and 5 (4%), without pedestal formations in zone 4, clear cancellous bone compressions in zone 6 (97.5%), as well as single fine scleroses (1.5%) and atrophies (2.5%) in zone 7. The mid-term clinical results with periprosthetic bone remodeling and without radiological signs of loosening confirm this metaphyseal short-stem treatment and fixation concept and the possibility of revision surgery using standard hip stems. Long-term results must be further observed on a prospective basis as part of this collective study.
منابع مشابه
Long-Term Follow-Up Results of a Second-Generation Cementless Femoral Prosthesis with a Collar and Straight Distal Fixation Channels
PURPOSE We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels. MATERIALS AND METHODS One hundred five patients (129 hips) who underwent surgery between 1991 and 1996 for primary total hip arthroplasty using cementless straight distal fluted femoral stems ...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملارزیابی عملکرد بیماران پس از آرتروپلاستی هیپ با پروتز Short-stem و Standard-stem : کارآزمایی بالینی تصادفی
Background: Short-stem prosthesis for total hip arthroplasty (THA) have been designed to overcome the weakness of standard-stem prostheses and improve surgical outcomes. The aim of this study was to compare short-stem with standard-stem prosthesis outcomes. Methods: This study was performed as a randomized clinical trial. Subjects were selected among patients referred to Sina University Hospit...
متن کاملAggressive granulomatous lesions in cementless total hip arthroplasty.
We describe six patients with aggressive granulomatous lesions around cementless total hip prostheses. Two patients previously had a cemented prosthesis in the same hip. The Lord prosthesis was used in five patients, the PCA in one. Both prostheses were made of chrome-cobalt alloy. Pain on weight-bearing occurred on average 3.2 years after the cementless arthroplasty, and at that time radiograp...
متن کاملInitial stability of a new uncemented short-stem prosthesis, Spiron®, in dog bone.
BACKGROUND Use of the proximal part of the femur in total hip arthroplasty enables preservation of the distal femur for later revisions. To use this advantage, different types of short-stem prosthesis have been developed in recent years. Although cementless hip arthroplasty is not common in the treatment of canine osteoarthritis, the use of cementless short-stems might be an alternative therapy...
متن کاملOutcomes of Dual Modular Cementless Femoral Stems in Revision Hip Arthroplasty
With an increasing number of primary hip replacements being performed every year, the burden of revision hip arthroplasty, for septic and aseptic loosening, recurrent dislocation or periprosthetic fracture, is also increasing. In recent years, different approaches to revising the femoral prosthesis have emerged; including both cemented and cementless techniques. With a stable cement mantle and ...
متن کامل