Improved Non-Selective T2-Prep with Adiabatic vs. Composite Pulses for Whole-Heart T2w Edema Imaging in Mice

نویسندگان

  • R. J. Beyers
  • Y. Xu
  • M. Salerno
  • S. S. Berr
  • C. H. Meyer
  • F. H. Epstein
چکیده

Introduction: An ongoing diagnostic challenge exists in quickly and reliably determining the area at risk (AR) for myocardial infarction (MI): i.e. the volume of potentially salvageable myocardium subtended by a coronary stenosis. T2w cardiac magnetic resonance (CMR) identifies the AR in large mammals by imaging post-ischemic edema. Previous T2w CMR studies have been performed in dogs, pigs and humans. However, in mice the fast heart rate, flow and motion present challenges to T2w CMR success. The typical 60 ms echo time for edema contrast occupies a large portion of the murine cardiac cycle which precludes using the same T2w methods used in larger mammals. Furthermore, a practical sequence must suppress the intraventricular bright blood and overcome the increase of B0 and B1 inhomogeneity artifacts that accompany a high-field 7T MR environment all while imaging the entire LV in under 15 minutes. Here, we expand a T2prep approach by comparing fast adiabatic vs. composite RF refocusing pulses. After development, we applied this sequence to image the entire left ventricle (LV) in post-MI mice and jointly applied late gadolinium enhanced (LGE) CMR to assess performance and demonstrate T2w imaging of the edematous AR compared to MI size as percent LV mass. Methods: We developed a whole-heart, multi-slice, T2w CMR sequence for mice with high immunity to flow and tissue motion artifacts and with dark-blood suppression that maintains sufficient signal-to-noise (SNR) and contrast-to-noise (CNR). Through-plane flow-sensitization gradients were applied during the T2prep to provide dark-blood capability. Through simulation, phantom and in vivo imaging, we developed a sequence that employed a non-selective T2prep with Malcolm Levitt-weighted (MLEV), selectable adiabatic or composite refocusing pulses, followed by a multislice, gradient-echo readout. We compared the performance of three refocusing pulse types: single rectangular (180y), composite (90x:180y:90x), and fast (2.4 ms) adiabatic refocusing pulses in MLEV-8 & 16 T2prep implementations. We simulated (Matlab) the three pulse types with simultaneous sweeps of ΔB0 (±1000 Hz) and ΔB1 (±50%) offset conditions with full relaxation modeling. We then imaged multiple T1 & T2 valued phantoms under manually-set ΔB0 (±2500 Hz) and ΔB1 (±50%) offsets. Finally, we performed in vivo CMR on post-MI mice to detect and track myocardial edema. We imaged three mice on Days 1 thru 4 after reperfused MI induced by 60-minute coronary occlusion. Imaging parameters included MLEV8 & 16, adiabatic pulse length = 2.4 ms, TR = 3 sec, TET2prep = 60 ms, FOV = 25 x 25 mm, slice thickness = 1 mm, matrix = 128 x 128, BW = 520 Hz/pixel. LGE CMR was also performed on Day 1 to define MI size after T2w CMR was completed. All scans were performed on a Bruker 7T ClinScan to cover the entire LV in 6 or 7 contiguous short axis slices in under 12 minutes scan time. Results: Simulation T2prep Mz output plots (Fig 1, panels A-C) show that both composite and adiabatic refocusing pulses are more resistant to B0 and B1 inhomogeneities compared to single rect refocusing pulses, where the composite and adiabatic pulses respectively gave 51.7 and 115.9 percent improvement over Single Rect pulses (change in green area, panels A-C). Separate phantom ΔB0 and ΔB1 imaging (Fig 1, panels D, E) verified that composite pulses doubled both ΔB0 coverage and ΔB1 tolerance while adiabatic pulses tripled both ΔB0 coverage and ΔB1 tolerance compared to single rect pulses. Figure 2, panels B, D present example in vivo Day 2 T2w myocardial edema images in mice that co-localize with LGE infarct pattern of panels A, C. These same panels also show effective flow sensitization dark-blood results and low occurrence of flow and motion artifacts. T2w image SNR was 68±4 and CNR measured between remote myocardium and AR regions was 34±2 (mean±SEM). At the whole-heart in vivo perspective, the composite pulses performed equally well as adiabatic pulses in both SNR and CNR with no measurable difference. However, in smaller regions of non-homogeneous B0 or B1 the adiabatic pulses are more tolerant. Overall edema tracking for 4 days post-MI gave a mean AR size of 46.7±1.5 percent LV mass. The mean MI size was 34.3±0.3, therefore, the AR was significantly (36.2%) larger than MI size (p < 0.01, ANOVA) with no significant change in AR size from Day 1 through 4. Likewise, the MI size was 73.4±1.2 percent of AR size. Conclusions: Although adiabatic pulses performed best with large simulated and phantom offsets, they did not completely out-perform composite pulses in vivo. This may be significant since composite pulses have a much lower specific absorption rate than do adiabatic pulses. T2w CMR in mice yielded results consistent with those reported in larger mammals. MLEV-16 outperformed MLEV-8 with better image homogeneity in the fast moving mouse hearts. Through T2w CMR, we demonstrated in mice that large MI resulting from an extended coronary occlusion (60-minute) left only 25±1.2 percent of the AR as potentially salvageable myocardium. T2w CMR can now be applied in knock-out mice to study the roles of individual genes and drug interventions on MI size as percent AR. Knowledge from these pre-clinical studies may translate toward improved techniques and therapies for humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

B1-insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T.

At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for cor...

متن کامل

Design of an adiabatic T2-preparation method optimized for cardiac motion and flow insensitivity at 3T

Background T2 contrast is important for the assessment of acute myocardial edema and coronary morphology. At 1.5T, the standard T2-prep method uses 4 composite 180° pulses (MLEV4 [1]) providing robust and uniform T2-preparation, but at 3T, increased B1 inhomogeneity causes artifacts. Decreasing inter-pulse spacing improves refocusing in the presence of motion and flow. We developed a configurab...

متن کامل

Pencil beam excitation using a 2D spatially selective adiabatic T2-prep for imaging the left coronary arterial system

Background 2D spatially selective radiofrequency (RF) pulses can be used to constrain the location from which an MR signal is obtained. This may lead to more time-efficient data collection by reducing the field of view (FoV) or may improve image quality by suppressing artefacts from outside the area of interest. Meanwhile, T2-Preparation, or T2-Prep, is a magnetization preparation scheme used t...

متن کامل

Adiabatic T2-preparation modules optimized for robustness toward cardiac motion and flow - a comparison with existing techniques at 3 Tesla

Background T2-imaging of the heart at 3 Tesla demands T2-preparations not only insensitive to B0 and B1, but also toward cardiac motion and flow in order to avoid flow artifacts and concomitant myocardial contamination and to preserve endocardial border definition. While more refocusing pulses per T2-prep duration improve robustness, they also increase SAR. We chose four BIREF-1 refocusing puls...

متن کامل

Simultaneous Quantitation of T1 and T2 Using a Novel 2D Magnetization-Prepared Multi-Slice Pulse Sequence

Introduction In recent years numerous approaches for the efficient, accurate and simultaneous quantitation of T1, T2, and M0 have been proposed – Ref 1 and 2 among them. Indeed, growing interest in generating synthetic MR images [2] and in “quantitative” tissue characterization continues to drive technical developments in MR relaxometry. Here we propose a novel 2D multi-slice pulse sequence tha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009