Permeation of Herbicidal Dichlobenil From a Casoron Formulation Through Nitrile Gloves
نویسندگان
چکیده
The aim of this study was to measure permeation of the herbicide dichlobenil in Casoron 4G through disposable and chemically protective nitrile gloves using an American Society for Testing and Materials-type permeation cell and a closed-loop system employing two different solvents (hexane and water) and two different challenge situations (aqueous emulsion and solid formulation). Capillary gas chromatography-mass spectrometry was used for quantification purposes. The chemically protective glove did not allow any permeation up to 8 h for the solid-formulation and water-collection challenges, but permeation was detected in all other challenges. The disposable glove allowed the most permeation, and the solid-formulation challenge with water collection necessitated that a dichlobenil equivalent be calculated because of the presence of its hydrolysis degradation product 2,6-dichlorobenzamide. Permeation from the solid formulation was detectable by hexane collection for both the disposable and chemically protective gloves and by water collection for the disposable glove. It was concluded that hexane-solvent collection was not valid for the disposable glove at 4 and 8 h of permeation in the solid Casoron challenge or for the aqueous emulsion challenge at 8 h relative to the water-collection solvent data. The hexane-solvent collection for the chemically protective glove was valid for the 8-h solid-formulation challenge but not for the 8-h aqueous-solution challenge. All water-solvent collections were valid; however, dichlobenil usually permeated the gloves.
منابع مشابه
Permeation of limonene through disposable nitrile gloves using a dextrous robot hand
OBJECTIVES The purpose of this study was to investigate the permeation of the low-volatile solvent limonene through different disposable, unlined, unsupported, nitrile exam whole gloves (blue, purple, sterling, and lavender, from Kimberly-Clark). METHODS This study utilized a moving and static dextrous robot hand as part of a novel dynamic permeation system that allowed sampling at specific t...
متن کاملمقایسه تأثیر استفاده از دستکش لاتکس و نیتریل بر مهارت دست در جمعیت ایرانی
Introduction: Manual dexterity impairment due to wearing latex and nitrile gloves among health care employees and laboratory personnel can be a remarkable problem because of its adverse outcomes. The present study was conducted to “compare the effect of using latex and nitrile laboratory gloves on hand dexterity”. .Material and Method: In a semi experimental study design, 30 university were s...
متن کاملEvaluation of the permeation of antineoplastic agents through medical gloves of varying materials and thickness and with varying surface treatments
BACKGROUND Medical gloves are an important piece of personal protective equipment that prevents exposure to antineoplastic agents. The permeability of medical gloves to antineoplastic agents is a crucial factor in the appropriate selection of gloves. However, the relationship between glove permeability and material type, thickness, and surface treatment is poorly understood. METHODS A continu...
متن کاملMethod of testing the penetration of acid solutions through safety gloves.
Because they cause burns that are difficult to heal, acids are dangerous, and steps should be taken to ensure that the human skin does not come into contact with them. For this purpose safety gloves are generally used by workers who have to handle acids. Such gloves need to be tested to ensure that they are acid resistant. Standard EN 374 (European Committee for Standardization [CEN], 1993c) sp...
متن کاملComparison of blood transmission through latex and nitrile glove materials.
AIMS To compare blood transmission through nitrile, single and double layer latex glove materials in simulated needlestick injuries. METHODS Experiments involved nitrile, single and double layer latex gloves. A cutting suture needle was dipped into a specimen of blood and then immediately jabbed through the glove material into a cell containing saline. This process was repeated using the same...
متن کامل