Open ended-coaxial Cable Measurements of Saturated Sandy Soils

نویسنده

  • Alberto Godio
چکیده

The application of electromagnetic methods in the radar and micro-wave frequency band allows the fluid content of soils to be estimated; the heuristic or physically-based models permit to relate the observed electrical permittivity of the soils with the porosity and fluid saturation. The role of the effect of the free water and bound water in the overall electromagnetic behaviour of soils is discussed. The measurements of the complex electrical permittivity of samples with different fluid content were carried out using an open ended coaxial cable in the frequency range between 0.2 and 6 GHz. The data processing permitted to estimate the water content with good accuracy; the slight overestimate of the values with respect to the standard laboratory measures of the fluid content is due to the propagation of the experimental uncertainties and to the effect of the bound water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficient and Accurate Full-Wave Analysis of the Open-Ended Coaxial Cable

An efficient implementation of the full-wave openended-coaxial-line analysis is presented in this paper. The involved integrals are approached in such a way that the admittance is accurately calculated. Moreover, the calculus time is noticeably reduced. This technique is particularly useful when repeated analysis are performed as occurs, e.g., when measuring permittivity.

متن کامل

Effects of Length and Diameter of Open-Ended Coaxial Sensor on its Reflection Coefficient

This paper presents a calibration technique for a coaxial sensor using a transmission signal approach. The sensor was fabricated from commercially available RG402/U and RG405/U semi-rigid coaxial cable. The length of the coaxial sensor was correlated with the attenuation and standing wave inside the coaxial line. The functions of multiple reflection amplitude and tolerance length with respect t...

متن کامل

Measurement of Complex Permittivity of Large Concrete Samples with an Open-Ended Coaxial Line

A 70 mm-open-ended coaxial line probe was developed to perform measurements of the dielectric properties of large concrete samples. The complex permittivity was measured in the frequency range 50 MHz – 1.5 GHz during the hardening process of the concrete. As expected, strong dependence of water content was observed.

متن کامل

Study of a Hybrid - Analog TV and Ethernet- Home Data Link using a Coaxial Cable

The paper presents an implementation and compatibility tests of a simple home network implemented in a nonconventional manner using a CATV coaxial cable. Reusing the cable, normally designated to supply RF modulated TV signals from cable TV networks, makes possible to add data services as well. A short presentation of the technology is given with an investigation of the main performances obtain...

متن کامل

Permittivity Measurements of Biological Samples by an Open-ended Coaxial Line

We previously reported on the complex permittivity and dc conductivity of waste-activated sludge. The measurements, spanning a frequency range of 3 MHz to 40 GHz, were made using an open-ended coaxial transmission line. Although this technique is well established in the literature, we found that it was necessary to combine methods from several papers to use the open-ended coaxial probe to relia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007