Refining the perfusion-diffusion mismatch hypothesis.

نویسندگان

  • K S Butcher
  • M Parsons
  • L MacGregor
  • P A Barber
  • J Chalk
  • C Bladin
  • C Levi
  • T Kimber
  • D Schultz
  • J Fink
  • B Tress
  • G Donnan
  • S Davis
چکیده

BACKGROUND AND PURPOSE The Echoplanar Imaging Thrombolysis Evaluation Trial (EPITHET) tests the hypothesis that perfusion-weighted imaging (PWI)-diffusion-weighted imaging (DWI) mismatch predicts the response to thrombolysis. There is no accepted standardized definition of PWI-DWI mismatch. We compared common mismatch definitions in the initial 40 EPITHET patients. METHODS Raw perfusion images were used to generate maps of time to peak (TTP), mean transit time (MTT), time to peak of the impulse response (Tmax) and first moment transit time (FMT). DWI, apparent diffusion coefficient (ADC), and PWI volumes were measured with planimetric and thresholding techniques. Correlations between mismatch volume (PWIvol-DWIvol) and DWI expansion (T2(Day 90-vol)-DWI(Acute-vol)) were also assessed. RESULTS Mean age was 68+/-11, time to MRI 4.5+/-0.7 hours, and median National Institutes of Health Stroke Scale (NIHSS) score 11 (range 4 to 23). Tmax and MTT hypoperfusion volumes were significantly lower than those calculated with TTP and FMT maps (P<0.001). Mismatch > or =20% was observed in 89% (Tmax) to 92% (TTP/FMT/MTT) of patients. Application of a +4s (relative to the contralateral hemisphere) PWI threshold reduced the frequency of positive mismatch volumes (TTP 73%/FMT 68%/Tmax 54%/MTT 43%). Mismatch was not significantly different when assessed with ADC maps. Mismatch volume, calculated with all parameters and thresholds, was not significantly correlated with DWI expansion. In contrast, reperfusion was correlated inversely with infarct growth (R=-0.51; P=0.009). CONCLUSIONS Deconvolution and application of PWI thresholds provide more conservative estimates of tissue at risk and decrease the frequency of mismatch accordingly. The precise definition may not be critical; however, because reperfusion alters tissue fate irrespective of mismatch.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PWI/DWI Mismatch: Better Definition Required

Definition Required To the Editor: In their recent study of perfusion-weighted (PWI) and diffusion-weighted (DWI) image analysis, Coutts et al1 have demonstrated the difficulties associated with interpretation of postprocessed perfusion maps. There are, however, more fundamental problems than PWI map interpretation in identifying patients with perfusion-diffusion mismatch. The first is a lack o...

متن کامل

PWI/DWI mismatch: better definition required.

Definition Required To the Editor: In their recent study of perfusion-weighted (PWI) and diffusion-weighted (DWI) image analysis, Coutts et al1 have demonstrated the difficulties associated with interpretation of postprocessed perfusion maps. There are, however, more fundamental problems than PWI map interpretation in identifying patients with perfusion-diffusion mismatch. The first is a lack o...

متن کامل

Rapid identification of a major diffusion/perfusion mismatch in distal internal carotid artery or middle cerebral artery ischemic stroke

BACKGROUND We tested the hypothesis that in patients with occlusion of the terminal internal carotid artery and/or the proximal middle cerebral artery, a diffusion abnormality of 70 ml or less is accompanied by a diffusion/perfusion mismatch of at least 100%. METHODS Sixty-eight consecutive patients with terminal ICA and/or proximal MCA occlusions and who underwent diffusion/perfusion MRI wit...

متن کامل

Methylene blue treatment delays progression of perfusion-diffusion mismatch to infarct in permanent ischemic stroke.

Stroke is a leading cause of morbidity and mortality in the world. Low-dose methylene blue (MB), which has been used safely to treat methemoglobinemia and cyanide poisoning in humans, has energy enhancing and antioxidant properties. We tested the hypothesis that methylene blue treatment delays progression of at-risk tissue (ca. perfusion-diffusion mismatch) to infarct in permanent middle cerebr...

متن کامل

Diffusion–Perfusion Mismatch: An Opportunity for Improvement in Cortical Function

OBJECTIVE There has been controversy over whether diffusion-perfusion mismatch provides a biomarker for the ischemic penumbra. In the context of clinical stroke trials, regions of the diffusion-perfusion mismatch that do not progress to infarct in the absence of reperfusion are considered to represent "benign oligemia." However, at least in some cases (particularly large vessel stenosis), some ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 2005