Does bone quality predict loosening of cemented total hip replacements?

نویسندگان

  • M Nixon
  • G Taylor
  • P Sheldon
  • S J Iqbal
  • W Harper
چکیده

We matched 78 patients with a loose cemented Charnley Elite Plus total hip replacement (THR) by age, gender, race, prosthesis and time from surgery with 49 patients with a well-fixed stable hip replacement, to determine if poor bone quality predisposes to loosening. Clinical, radiological, biomechanical and bone mineral density indicators of bone quality were assessed. Patients with loose replacements had more pain, were more likely to have presented with atrophic arthritis and to have a history of fragility fracture, narrower femoral cortices and lower peri-prosthetic or lumbar spine bone mineral density (all t-test, p < 0.01). They also tended to be smokers (chi-squared test, p = 0.08). Vitamin-D deficiency was common, but not significantly different between the two groups (t-test, p = 0.31) In this series of cemented hip replacements performed between 1994 and 1998, aseptic loosening was associated with poor bone quality. Patients with a THR should be screened for osteoporosis and have regular radiological surveillance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hypersensitivity in aseptic loosening of total hip replacements. The role of constituents of bone cement.

Aseptic loosening is seen in a significant proportion of cemented total hip replacements (THR). In a small subgroup of patients who suffer early loosening polyethylene debris is unlikely to be responsible. We recently reported one case of allergic contact dermatitis to N,N-dimethylparatoluidine (DMT), an accelerator used in bone cement. We have therefore investigated this using skin-patch tests...

متن کامل

News-Screen Osteologie

Measurement of skin thickness has been proposed as a method of predicting low bone mineral density (BMD) and the consequent risk of osteoporotic fracture in postmenopausal women. The Episcan I-100 device is a new type of ultrasound device that uses high-frequency (20 MHz) ultrasound to measure skin thickness using a small probe placed on the skin. The aims of this study were to investigate whet...

متن کامل

Stanmore total hip replacement in younger patients: review of a group of patients under 50 years of age at operation.

Fifty-seven Stanmore Total Hip replacements were implanted between 1974 and 1986 in patients under the age of 50 years. We have reviewed the results in terms of survivorship and function, and assessed the reasons for revision. Of the original 57, 22 (39%) have been revised at an average of 12 years from implantation, usually for aseptic loosening. Most of them had originally been implanted for ...

متن کامل

Total hip replacement with a superolateral bone graft for osteoarthritis secondary to dysplasia: a long-term follow-up.

We evaluated the long-term results of 116 total hip replacements with a superolateral shelfplasty in 102 patients with osteoarthritis secondary to developmental dysplasia of the hip. After a mean follow-up of 19.5 years (11.5 to 26.0), 14 acetabular components (12%) had been revised. The cumulative survival at 20 years was 78%, with revision for loosening of the acetabular component as the end-...

متن کامل

Analysis of Cement Mantle in Relation to Surgical Approach

Aseptic loosening remains the commonest cause of failure of total hip arthroplasty. Cement mantle defects are associated with aseptic loosening. Cementing technique has a profound influence on the incidence of aseptic loosening of total hip replacements. Two specific measures that seem to have the greatest impact on the longevity of cemented femoral stems are pressurization of cement and contro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 89 10  شماره 

صفحات  -

تاریخ انتشار 2007