Design and Evaluation of Potentiometric Principles for Bladder Volume Monitoring: A Preliminary Study

نویسندگان

  • Shih-Ching Chen
  • Tsung-Hsun Hsieh
  • Wen-Jia Fan
  • Chien-Hung Lai
  • Chun-Lung Chen
  • Wei-Feng Wei
  • Chih-Wei Peng
چکیده

Recent advances in microelectronics and wireless transmission technology have led to the development of various implantable sensors for real-time monitoring of bladder conditions. Although various sensing approaches for monitoring bladder conditions were reported, most such sensors have remained at the laboratory stage due to the existence of vital drawbacks. In the present study, we explored a new concept for monitoring the bladder capacity on the basis of potentiometric principles. A prototype of a potentiometer module was designed and fabricated and integrated with a commercial wireless transmission module and power unit. A series of in vitro pig bladder experiments was conducted to determine the best design parameters for implementing the prototype potentiometric device and to prove its feasibility. We successfully implemented the potentiometric module in a pig bladder model in vitro, and the error of the accuracy of bladder volume detection was <±3%. Although the proposed potentiometric device was built using a commercial wireless module, the design principles and animal experience gathered from this research can serve as a basis for developing new implantable bladder sensors in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potentiometric Method to Determine Montelukast Sodium in its Tablets with In-line Monitoring of its Dissolution Behaviour

Direct drug determination without any pervious treatment steps is the most environmentally friendly method of analysis. Traditional analysis methods usually involve a pre-treatment step before analysis and this consumes time and organic solvents. This work describes direct potentiometric method by using ion selective electrode to determine Montelukast Sodium in its pure drug substance and in ta...

متن کامل

A Preliminary Investigation into Geometry, Represented by Parameters, and its Effect on Function and Manufacturing Attributes

  This paper demonstrates a preliminary investigation of geometry, function and its relation to DFX principles, namely DFM (Design for Manufacturing). This is the starting point for research on the development of an expert system that assesses design goals along DFX principles in a feature-based CAD environment. There is a need for a deeper level of understanding of the relationship between geo...

متن کامل

A Green Potentiometric Application for Selective Monitoring of Doxylamine Succinate Dissolution Profile in Combined Dosage Form

"Green analytical chemistry" (GAC) succeeded to become an eco-friendly environmental crucial area in the field of analytical chemistry targeting at the chemical processes' and products' optimization regarding to material consumption, generation of waste and intrinsic safety, toxicity and environmental burdens. For an expressive comparison, an electro-analytical in-line potentiometric selective ...

متن کامل

Instructional Design, Implementation, and Evaluation of an E-Learning System, an Experience in Tehran University of Medical Sciences

Introduction: Designing e-learning systems based on the principles and prerequisites of teaching and learning theories requires a comprehensive and systematic approach to instructional design procedure. An experience of instructional design, implementation and evaluation of an e-learning system is represented in this study. Methods: In the present action research study, five steps of systemati...

متن کامل

Design and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention

Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer preventio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015