Relationship between bispectral index, auditory evoked potential index and effect-site EC50 for propofol at two clinical end-points.
نویسندگان
چکیده
BACKGROUND Many anaesthetists are deterred from using total i.v. anaesthesia because of uncertainty over the concentration of propofol required to prevent awareness. We predicted blood and effect-site concentrations of propofol at two clinical end-points: loss of consciousness and no response to a painful stimulus. METHODS Forty unpremedicated Caucasian patients were anaesthetized with i.v. propofol delivered by a Diprifusor target-controlled infusion (TCI). Bispectral index (BIS) and auditory evoked potential index (AEPex) were measured and blood and effect-site propofol concentrations were predicted. Logistic regression was used to estimate population values for predicted blood and effect-site propofol concentrations at the clinical end-points and to correlate these with BIS and AEPex. RESULTS The effect-site EC(50) at loss of consciousness was 2.8 micro m ml(-1) with an EC(05) and an EC(95) of 1.5 and 4.1 micro m ml(-1), respectively. The predicted EC(50) when there was no response to a tetanic stimulus was 5.2 micro m ml(-1) with an EC(05) and an EC(95) of 3.1 and 7.2 micro m ml(-1), respectively. CONCLUSIONS Unconsciousness and lack of response to a painful stimulus occur within a defined range of effect-site concentrations, predicted by Diprifusor TCI software.
منابع مشابه
A comparison between bispectral index analysis and auditory-evoked potentials for monitoring the time to peak effect to calculate the plasma effect site equilibration rate constant of propofol.
BACKGROUND AND OBJECTIVES To the best of our knowledge, the value of the plasma effect site equilibration rate constant (k(e0)) of propofol has not been reported in Chinese patients. The aim of this prospective, randomized study was to examine the characteristics of the time to peak effect (T(PEAK)) of propofol, a pharmacokinetic-independent descriptor of blood-brain equilibration, and k(e0) de...
متن کاملNew composite index based on midlatency auditory evoked potential and electroencephalographic parameters to optimize correlation with propofol effect site concentration: comparison with bispectral index and solitary used fast extracting auditory evoked potential index.
BACKGROUND This study investigates the accuracy of a composite index, the A-Line(R) auditory evoked potentials index version 1.6 (AAI1.6; Danmeter A/S, Odense, Denmark), as a measure of cerebral anesthetic drug effect in a model for predicting a calculated effect site concentration of propofol (CePROP). The AAI1.6 algorithm extracts information from the midlatency auditory evoked potentials, th...
متن کاملRelationship between calculated blood concentration of propofol and electrophysiological variables during emergence from anaesthesia: comparison of bispectral index, spectral edge frequency, median frequency and auditory evoked potential index.
We studied four electrophysiological variables (bispectral index (BIS), 95% spectral edge frequency (SEF), median frequency (MF) and auditory evoked potential index (AEP index) in 10 patients during emergence from anaesthesia. We compared correlation of the signals with gradually decreasing calculated blood propofol concentrations, and evaluated the signal differences between preinduction and e...
متن کاملPrediction of movement at laryngeal mask airway insertion: comparison of auditory evoked potential index, bispectral index, spectral edge frequency and median frequency.
We have studied 46 patients to compare the efficacy of the auditory evoked potential (AEP) index, bispectral index (BIS), 95% spectral edge frequency (SEF) and median frequency (MF) in predicting movement in response to insertion of the laryngeal mask airway (LMA). Anaesthesia was induced with target-controlled infusions of propofol and alfentanil. After loss of eyelash reflex and adequate jaw ...
متن کاملComparison of bispectral EEG analysis and auditory evoked potentials for monitoring depth of anaesthesia during propofol anaesthesia.
We have compared the auditory evoked potential index (AEPIndex) and bispectral index (BIS) for monitoring depth of anaesthesia in spontaneously breathing surgical patients. Twenty patients (aged 17-49 yr) undergoing day surgery were anaesthetized with computer-controlled infusions of propofol. The mean (SD and range) of each measurement was determined during consciousness and unconsciousness an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 90 2 شماره
صفحات -
تاریخ انتشار 2003