Using sweeping micellar electrokinetic chromatography to analyze Delta9-tetrahydrocannabinol and its major metabolites.
نویسندگان
چکیده
We have applied sweeping micellar electrokinetic chromatography (sweeping-MEKC) to the simultaneous determination of Delta(9)-tetrahydrocannabinol (THC) and its major metabolites, 11-hydroxy-Delta(9)-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH). We monitored the effects of several of the sweeping-MEKC parameters, including the proportion of organic modifier, the concentration of sodium dodecyl sulfate (SDS), the pH, and the sample injection volume, to optimize the separation process. The optimal buffer for the analysis of the three analytes was 25 mM citric acid/disodium hydrogenphosphate (pH 2.6) containing 40% methanol and 75 mM SDS. Under the optimized separation parameters, the enrichment factors for THC, THC-COOH, and THC-OH when using sweeping-MEKC (relative to MEKC) were 77, 139, and 200, respectively. The limits of detection (LODs) for the three compounds in standard solutions ranged from 3.87 to 15.2 ng/mL. We combined the sweeping-MEKC method with solid-phase extraction to successfully detect THC, THC-COOH, and THC-OH in human urine with acceptable repeatability. The LODs of these analytes in urine samples ranged from 17.2 to 23.3 ng/mL. Therefore, this sweeping-MEKC method is useful for determining, with high sensitivity, the amounts of THC and its metabolites in the urine of suspected THC users.
منابع مشابه
Sweeping technique combined with micellar electrokinetic chromatography for the simultaneous determination of flunitrazepam and its major metabolites.
A sweeping technique, in conjunction with micellar electrokinetic chromatography, for the simultaneous determination of flunitrazepam and its major metabolites, 7-aminoflunitrazepam and N-desmethylflunitrazepam, is described. The optimized conditions for the sweeping and separation were a pH 9.5 buffer, 25mM borate, 50mM cetyltrimethylammonium bromide, 30% MeOH (v/v), and a 151-mm injection len...
متن کاملOn-line preconcentration and determination of ketamine and norketamine by micellar electrokinetic chromatography. Complementary method to gas chromatography/mass spectrometry.
We have investigated a rapid, simple, and highly efficient on-line preconcentration method using in micellar electrokinetic chromatography (MEKC) for the analysis of abused drugs. Ketamine is an anesthetic that has been abused as a hallucinogen. We applied the sample sweeping technique first to ketamine and its major metabolite, norketamine, and separated the analytes with MEKC. Several of the ...
متن کاملOptimization of the separation of lysergic acid diethylamide in urine by a sweeping technique using micellar electrokinetic chromatography.
The separation and on-line concentrations of lysergic acid diethylamide (LSD), iso-lysergic acid diethylamide (iso-LSD) and lysergic acid N,N-methylpropylamide (LAMPA) in human urine were investigated by capillary electrophoresis-fluorescence spectroscopy using sodium dodecyl sulfate (SDS) as an anionic surfactant. A number of parameters such as buffer pH, SDS concentration, Brij-30 concentrati...
متن کاملUsing cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography to determine selective serotonin reuptake inhibitors.
We have employed a rapid and highly efficient on-line preconcentration method, cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-sweeping-MEKC), for the analysis of selective serotonin reuptake inhibitors (SSRIs) of antidepressant drugs. We monitored the effects of several of the CSEI-sweeping-MEKC parameters - including the pH, the concentrations o...
متن کاملDetermination of lysergic acid diethylamide (LSD) by application of online 77 K fluorescence spectroscopy and a sweeping technique in micellar electrokinetic chromatography.
The principal advantage of the use of Shopl'skii effect (low temperature spectrum) is that spectral sharpening occurs both in absorption and emission. However, thus far using the technique of capillary electrophoresis/low temperature fluorescence spectroscopy (CE/LTFS) either at 77 or 4.2 K remains difficult to obtain an on-line spectrum, if the analyte is present at low concentration. This pap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1216 16 شماره
صفحات -
تاریخ انتشار 2009