Position of rigid and foldable iris-fixated myopic phakic intraocular lenses evaluated by Scheimpflug photography.

نویسندگان

  • Thomas Kohnen
  • Magda Cichocki
  • Michael J Koss
چکیده

PURPOSE To evaluate the postoperative intraocular positional stability of 1 rigid poly(methyl methacrylate) (PMMA) phakic intraocular lens (pIOL) model and 2 foldable polysilicone-PMMA iris-fixated pIOL models. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University Frankfurt am Main, Germany. METHODS One of 3 iris-fixated pIOL models (Artisan, Artiflex I, and Artiflex II, Ophtec BV) was implanted in 45 eyes of 26 patients with myopia or myopic astigmatism. The central distance between the pIOL and corneal endothelium and between the pIOL and anterior surface of the crystalline lens was evaluated using Scheimpflug photography 6 and 12 months after surgery. RESULTS The mean preoperative spherical equivalent was -9.32 diopters +/- 1.78 (SD) (range -6.5 to -13.5 D). Each IOL model was implanted in 15 eyes. The median distance from the central corneal endothelium to the anterior surface of the pIOL at 6 months and 12 months was 2.65 mm and 2.64 mm, respectively, in the Artisan group, 2.47 mm and 2.50 mm, respectively, in the Artiflex I group, and 2.48 mm and 2.52 mm, respectively, in the Artiflex II group. The median distance between the posterior surface of the pIOL and the anterior surface of the crystalline lens at 6 months and 12 months was 0.40 mm and 0.48 mm, respectively, in the Artisan group, 0.53 mm and 0.55 mm, respectively, in the Artiflex I group, and 0.68 mm and 0.66 mm, respectively, in the Artiflex II group. At 12 months, the distance between the pIOL and crystalline lens was statistically significantly greater in the Artiflex II group than in the Artisan group (P<.01). CONCLUSION The intraocular position of rigid pIOLs and foldable silicone iris-supported pIOLs showed a difference between the 3 pIOL models in space to the crystalline lens and the corneal endothelium, which may affect long-term results in terms of IOL interaction with surrounding tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism

PURPOSE To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. MATERIALS AND METHODS The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixa...

متن کامل

Short-term follow-up after implantation of a foldable iris-fixated intraocular lens in phakic eyes.

OBJECTIVE To evaluate efficiency, predictability, stability, complications, and patient satisfaction after implantation of a foldable iris-fixated phakic intraocular lens (PIOL) for the correction of myopia. DESIGN Prospective, nonrandomized, comparative (self-controlled) trial. PARTICIPANTS Forty-one eyes of 22 myopic patients aged 18 to 56 years (mean, 36 years) with average sphere of -8....

متن کامل

Prominent decrease of superior midperipheral endothelial cell density after iris-fixated phakic intraocular lens implantation.

PURPOSE To evaluate changes in endothelial cell density (ECD) in the corneal region after implantation of an iris-fixated phakic intraocular lens (PIOL). METHODS Forty-five eyes of 25 myopic patients implanted with Artisan iris-fixated PIOLs (Ophtec BV) and 30 eyes of 15 myopic controls were enrolled. Corneal ECD and the distance between endothelium and the PIOL optic were evaluated in five d...

متن کامل

Traumatic Partial Aniridia and Cataract after Iris-Fixated Foldable Phakic Intraocular Lens Implantation

We present the first case of partial aniridia, traumatic cataract, and peripapillary subretinal hemorrhage after blunt trauma to an eye containing a foldable iris-fixated phakic intraocular lens (pIOL). Although the patient experienced visual loss because of considerable corneal astigmatism and a traumatic cataract, vision was recovered by a 2-stage primary corneal repair and cataract surgery w...

متن کامل

Intermittent myopic shift of 4.0 diopters after implantation of an Artisan iris-supported phakic intraocular lens.

A 45-year-old man with bilateral high myopia and myopic astigmatism had uneventful implantation of a -10.5 diopters (D) Artisan iris-fixated anterior chamber phakic intraocular lens (PIOL) (Ophtec) in both eyes. In the first days after surgery, uncorrected visual acuity (UCVA) was 20/16 in the right eye and 20/16 in the left; the position of the PIOL was stable. Ten days after surgery, the left...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 2008