2010 mid-America Orthopaedic Association Physician in Training Award: healing complications are common after locked plating for distal femur fractures.

نویسندگان

  • Christopher E Henderson
  • Trevor J Lujan
  • Lori L Kuhl
  • Michael Bottlang
  • Daniel C Fitzpatrick
  • John L Marsh
چکیده

BACKGROUND Several mechanical studies suggest locking plate constructs may inhibit callus necessary for healing of distal femur fractures. However, the rate of nonunion and factors associated with nonunion are not well established. QUESTIONS/PURPOSES We (1) determined the healing rate of distal femur fractures treated with locking plates, (2) assessed the effect of patient injury and treatment variables on fracture healing, and (3) compared callus formation in fractures that healed with those that did not heal. PATIENTS AND METHODS We retrospectively reviewed 82 patients treated with 86 distal femur fractures using lateral locking plates. We reviewed all charts and radiographs to determine patient and treatment variables and then determined the effects of these variables on healing. We quantitatively measured callus at 6, 12, and 24 weeks. The minimum time for telephone interviews and SF-36v2(TM) scores was 1 year (mean, 4.2 years; range, 1-7.2 years). RESULTS Fourteen fractures (20%) failed to unite. Demographics and comorbidities were similar in patients who achieved healing compared with those who had nonunions. There were more empty holes in the plate adjacent to fractures that healed; comminuted fractures failed to heal more frequently than less comminuted fractures. Less callus formed in fractures with nonunions and in patients treated with stainless steel plates compared with titanium plates. Complications occurred in 28 of 70 fractures (40%), 19 of which had additional surgery. CONCLUSIONS We found a high rate of nonunion in distal femur fractures treated with locking plates. Nonunion presented late without hardware failure and with limited callus formation suggesting callus inhibition rather than hardware failure is the primary problem. Mechanical factors may play a role in the high rate of nonunion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SOCIETY AWARDS 2010 Mid-America Orthopaedic Association Physician in Training Award: Healing Complications Are Common After Locked Plating for Distal Femur Fractures

Background Several mechanical studies suggest locking plate constructs may inhibit callus necessary for healing of distal femur fractures. However, the rate of nonunion and factors associated with nonunion are not well established. Questions/purposes We (1) determined the healing rate of distal femur fractures treated with locking plates, (2) assessed the effect of patient injury and treatment ...

متن کامل

Are extreme distal periprosthetic supracondylar fractures of the femur too distal to fix using a lateral locked plate?

It is unclear whether there is a limit to the amount of distal bone required to support fixation of supracondylar periprosthetic femoral fractures. This retrospective multicentre study evaluated lateral locked plating of periprosthetic supracondylar femoral fractures and compared the results according to extension of the fracture distal with the proximal border of the femoral prosthetic compone...

متن کامل

Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.

OBJECTIVES Locked plating constructs may be too stiff to reliably promote secondary bone healing. This study used a novel imaging technique to quantify periosteal callus formation of distal femur fractures stabilized with locking plates. It investigated the effects of cortex-to-plate distance, bridging span, and implant material on periosteal callus formation. DESIGN Retrospective cohort stud...

متن کامل

Far Cortical Locking Enables Flexible Fixation While Maintaining Construct Strength

INTRODUCTION: The stiffness of a fixation construct affects the mechanism and progression by which a fracture heals. Locked plating constructs have improved fixation strength in weak bone, but their relatively high stiffness may suppress interfragmentary motion (IFM) to a level insufficient for optimal promotion of secondary bone healing.[1] This is especially of concern when locked plates are ...

متن کامل

The Outcome and Complications of the Locked Plating Management for the Periprosthetic Distal Femur Fractures after a Total Knee Arthroplasty

BACKGROUND The osteosynthesis of the periprosthetic fractures following a total knee arthroplasty (TKA) can be technically difficult with the relatively small satisfactory outcomes and the high complication rates. The purpose of the study is to analyze the mid-term radiological and functional outcomes following the locked plating of the distal femur periprosthetic fractures after a TKA. METHO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 469 6  شماره 

صفحات  -

تاریخ انتشار 2011