Wear Properties of UHMWPE in CHARITE َ Artificial Inter-vertebral Disc
نویسنده
چکیده
Over the past three decades more than a half a million joint replacements have been performed. Several advances have been made to the design of the implants, but despite the large success of these procedures, loosening of the components and periprosthetic osteolysys often requires a revision surgery. In looking at what causes this, the wear of the UHMWPE articulation surface and the associated biological reactions to the wear debris have emerged as a major problem in total joint replacements. The main reason for wear testing is to determine the device durability, looking for potential failure modes such as fracture, or excessive wear that may lead to compromised function. The other reason is to try to predict the effect the device may have on the body. Neurotoxicity, inflammation, oncogenesis and osteolysis are all side effects that may be present when a device is implanted in the body and have been seen in cases with hip and knee replacement. In determining the durability of an implant you first must know the types of loads that the device will be exposed to. These can be taken from research done over the past several years (see Figure1). Different loading conditions and motion controls must also be considered when testing these implants. Debates continue on the most physiologically accurate method for setting up test parameters. Current testing has shown wear debris testing of the CHARITE artificial disc to be significantly lower than the artificial hip and knee implants under similar loading conditions. When a cross-path motion loading condition is compared to curvilinear motion loading condition it can be seen that there is also significantly more wear with a cross-path motion profile. The large discrepancy in the amount of wear that can be achieved based on a different motion profile is an important consideration in the design and further development of medical devices. For future development, there are several areas that will require research. The first is to look at the effects of sterilization methods of the UHMWPE on fatigue performance. The second is to try to gain a better understanding of loads that the body may undergo during daily activities. The third is to determine the most accurate method of testing devices concerning motion and loading parameters.
منابع مشابه
Storing Period Effects on Wear Properties in Uhmwpe Inserts for Artificial Joints
INTRODUCTION Artificial joints have been increasingly used in treatment of physically disabled people who have severely damaged joints. In artificial joint, ultra high molecular weight polyethylene (UHMWPE) has been usually employed as a buffer because of its very low friction coefficient, high wear resistance, high impact strength, and biocompatibility. [1]. When artificial joints were replace...
متن کاملEffects of Gamma Irradiation and Accelerated Aging on Wear Properties of UHMWPE Artificial Joint
Oxidative degradation of ultra-high molecular weight polyethylene (UHMWPE; PE), due to gamma irradiation sterilization in air, increases wear rate in artificial joint. Not only adhesive and abrasive wear but also delamination (flaking), a typical wear of the PE component in artificial knee joint, and fracture could be observed. This paper deals with gamma-irradiation effects on severe wear mech...
متن کاملQuantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation.
Ultra-high-molecular-weight polyethylene (UHMWPE) components for total joint replacement generate wear particles which cause adverse biological tissue reactions leading to osteolysis and loosening. Sterilisation of UHMWPE components by gamma irradiation in air causes chain scissions which initiate a long-term oxidative process that degrades the chemical and mechanical properties of the polyethy...
متن کاملBiomechanical Properties of Dispersep Article Reinforced Polymer Composites on Ultrahigh Molecular Weight Polyethylene (UHMWPE)
Ultrahigh molecular weight polyethylene (UHMWPE) having a low coefficient of friction (CoF), high wearand chemical resistance in harsh environments, is used for fabricating medical products (hip and knee joints, intervertebral discs, plates for maxillofacial surgery, and others). Priority of polymers, in particular UHMWPE to be applied as medical implant materials, is due to their proximity to ...
متن کاملPotential for adhesive wear in friction couples of UHMWPE running against oxidized zirconium, titanium nitride coatings, and cobalt-chromium alloys.
The classical wear mechanisms abrasion, fatigue, and adhesion are the most frequent causes of surface changes of ultra high molecular weight polyethylene (UHMWPE) in artificial joints. The counterpart material has a strong influence on the wear and friction behavior of artificial joints due to its abrasive properties and adhesive interaction with UHMWPE. The formation of a transfer layer on the...