In vivo 19F magnetic resonance spectroscopy and chemical shift imaging of tri-fluoro-nitroimidazole as a potential hypoxia reporter in solid tumors.

نویسندگان

  • Daniel Procissi
  • Filip Claus
  • Paul Burgman
  • Jacek Koziorowski
  • J Donald Chapman
  • Sunitha B Thakur
  • Cornelia Matei
  • C Clifton Ling
  • Jason A Koutcher
چکیده

PURPOSE 2-Nitro-alpha-[(2,2,2-trifluoroethoxy)methyl]-imidazole-1-ethanol (TF-MISO) was investigated as a potential noninvasive marker of tissue oxygen levels in tumors using (19)F magnetic resonance spectroscopy (MRS) and (19)F chemical shift imaging. EXPERIMENTAL DESIGNS In vitro data were obtained using high-performance liquid chromatography on tumor cells incubated under varying oxygen conditions to determine the oxygen-binding characteristics. In vivo data were obtained using a well-characterized hypoxic murine breast tumor (MCa), in addition to studies on a rat prostate tumor model (R3327-AT) implanted in nude mice. Detection of intratumor (19)F signal from TF-MISO was done using MRS for up to 10 h following a 75 mg/kg i.v. injection. Localized distribution of the compound in the implanted MCa tumor has been imaged using slice-selective two-dimensional chemical shift imaging 6 h after injection. RESULTS The in vitro results showed that TF-MISO preferentially accumulates in cells incubated under anoxic conditions. The in vivo (19)F MR spectral features (line width and chemical shift) were recorded as a function of time after injection, and the results indicate that the fluorine atoms are indeed sensitive to changes in the local environment while still providing a detectable MR signal. Ex vivo spectra were collected and established the visibility of the (19)F signal under conditions of maximum hypoxia. Late time point (>6 h) tumor tissue concentrations, as obtained from (19)F MRS, suggest that TF-MISO is reduced and retained in hypoxic tumor. The feasibility of obtaining TF-MISO tumor distribution maps in a reasonable time frame was established. CONCLUSIONS Based on the results presented herein, it is suggested that TF-MISO has the potential to be a valid magnetic resonance hypoxia imaging reporter for both preclinical hypoxia studies and hypoxia-directed clinical therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

2-Nitroimidazole as Potential Nanoprobe in Hypoxia Imaging by MRI/PET

2-Nitroimidazole is radiosensitizer and serves as imaging contrast agent by 19Fand 31P MR methods. Despite the success of mesonidazole and SR-4554 compounds, very little is known of its hepato-cytotoxicity if it can be potential hypoxia imaging marker and non-toxic drug. Authors established the low oxygen, low energy metabolic ratio and gluconeogenesis in nitroimidazole induced hepatocytes and ...

متن کامل

Quantitation of 5-fluorouracil catabolism in human liver in vivo by three-dimensional localized 19F magnetic resonance spectroscopy.

The development of clinical applications of 19F magnetic resonance (MR) spectroscopy of 5-fluorouracil (5-FU) has been limited by the inability to localize 19F spectra to specific regions of interest, making it difficult to quantitate drug and metabolite concentrations accurately. To develop methodology for quantitation, we studied the liver of patients receiving rapid bolus i.v. injections of ...

متن کامل

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

Responsive fluorinated lanthanide probes for 19F magnetic resonance spectroscopy.

The introduction of CF(3) reporter groups close to the paramagnetic centre in macrocyclic lanthanide(iii) complexes allows faster acquisition of (19)F magnetic resonance data, and amplifies chemical shift non-equivalence, as exemplified by the definition of ratiometric chemical shift probes for pH and, in principle, enzyme activity.

متن کامل

The Utility of Diffusion Weighted Magnetic Resonance Imaging in Detection of the Origin of the Brain Solid Metastatic Tumors

Background: Early diagnosis of brain tumors has significant effect on the treatment process. Brain metastatic tumors are usually diagnosed following the neurological symptoms in patients or incidentally after Computerized Tomography (CT) scan and Magnetic Resonance Imaging (MRI) requests of the brain. Objectives: Implementation of a new method for being informed about the origin of brain tumors...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical cancer research : an official journal of the American Association for Cancer Research

دوره 13 12  شماره 

صفحات  -

تاریخ انتشار 2007