Computational modeling of amperometric choline biosensor for neurochemical detection
نویسندگان
چکیده
The behavior of biosensors is based on the well-defined physical, chemical and biological reactions, which are expressed by nonlinear differential equations. The characteristics of diffusion reaction of choline biosensor are analyzed mathematically for wide range of input parameters such as initial concentration of choline and thickness of choline oxide enzyme layer. The mathematical simulations are done in MATLAB software using partial differential equation solver pdepe function. The analytical results are compared with numerically simulated results for various conditions to validate the model parameters. A numerical simulation result shows less than 2% deviation from analytical results for various substrate concentrations. For dimensionless diffusion distance x=0 and sigma=1, the dimensionless substrate and product concentrations are 0.72 and 0.18 when t=1 and changes exponentially with time.
منابع مشابه
Evaluation of Different Functionalized CNTs for Development of Choline Amperometric Biosensor
Choline oxidase (ChOx) was chosen as a model enzyme for evaluating the performance of CNTs’ functional groups for development of enzyme electrodes. CNTs were functionalized with carboxylic acid, amine or amide groups. Carboxylic acid, amine and amide functionalized CNTs were obtained by acid treatment, ethylenediamine or tetraethylenepentamine chemically modification and ammonia plasma treatmen...
متن کاملAMPEROMETRIC MICROBIOSENSOR FOR THE DETERMINATION OF CHOLINE
The construction and performance of an amperometric microbiosensor for the determination of choline chloride by immobilizing choline oxidase on a cellulose acetate membrane are described. The procedure of choline determination involved the electrochemical detection of enzymatically generated hydrogen peroxide. This microsensor has a linear response between 0.038-0.1 mM choline chloride. The...
متن کاملComparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission
Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...
متن کاملA Novel Choline Biosensor Based on Immobilization of Enzyme Choline Oxidase on the β-Ga2O3 Nanowires Modified Working Electrode
This article is a report on a novel and high-stability biosensor with minor interference effects of surface modification of working electrode with β-Ga2O3 nanowires (NWs) on choline oxidase biosensor were investigated in an electrochemical detection system. β-Ga2O3 NWs were materialized on the silicon substrate in a catalyst-free growth mechanism. The β-Ga2O<sub...
متن کاملMediated enzyme screen-printed electrode probes for clinical, environmental and food analysis
Since the appearance of the first amperometric biosensors based on the coupling of oxidase enzymes and relying on the final detection of H2O2, it was clear that one of the major problems related to this kind of configuration was due to the high overpotential needed for H2O2 oxidation (ca. 0.7V vs. Ag/AgCl). At this potential in fact, many electroactive substances (i.e. ascorbic acid, uric acid ...
متن کامل