Non - invasive Bio - impedance Measurement Using Voltage - Current Pulse Technique

نویسنده

  • Sagar K. Dhar
چکیده

Noninvasive detection is a fundamental prerequisite for pervasive healthcare system and biosensing. Along with different noninvasive techniques such as ultrasound, X-ray, magnetic resonance and optical imaging, electrical impedance spectroscopy is emerging as more suitable technique for tissue level diagnosis. This paper presents a noninvasive technique for bioelectrical impedance estimation by means of impedance spectroscopy applying voltagecurrent pulse technique and least square curve fitting method. Simple circuit for current injection and voltage detection is presented with common mode noise suppression circuit requires only two electrodes would reduce problems due to electrode polarization. The current source is presented with constant output current as low as 100 μA, about 1MΩ load variation and 10 MHz mid-range bandwidth. Voltage detection and impedance estimation is done with Data Acquisition (DAQ) tool box of Matlab R2008a and curve fitting technique. Successful simulation results in bioelectrical impedance estimation are found with 1.5% maximum error; suggest impedance measurement below 100 kHz because of higher response of permittivity and conductivity of biological tissues in this band than the high frequency band (MHz band). Keywords—bioelectrical impedance, impedance spectroscopy, curve fitting, data acquisition tool box, non-invasive biosensing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

قلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی

 Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...

متن کامل

Transient Reduction in Pulse-Based Impedance Measurements

Abstrac t Impedance measurements based on voltage pulse injection and current detection are faster and easier to implement than measurements based on sine waves, but transients produced in the current-to-voltage conversion may lead to large deviations in the measurement result. Because those transients depend on the same impedance being measured, solutions based on specific circuit values fail ...

متن کامل

Characterization of Physiological Glucose Concentration Using Electrical Impedance Spectroscopy

Non-invasive glucose monitoring is crucial for effective diabetes mellitus treatment while a sound correlation of a non-invasive parameter to glucose level variation is quite challenging. This paper presents characterization of glucose concentrations using Electrical Impedance Spectroscopy (EIS) in three different solutions: 1) 0.9% NaCl, 2) Saline (NaCl 1.3gm, KCl 0.75gm, Na3C6H5O7 1.45gm, D-g...

متن کامل

Harmonic Reduction Technique Using Flying Capacitor Based Z Source Inverter for a DVR

The Dynamic Voltage Restorer (DVR) is a commercially available, popular device to eliminate voltage sags and swells in the distribution lines. Its basic function is to inject the voltage difference (difference between the pre-sag and sag voltage) to the power line and maintains the pre-sag voltage condition in the load side. The efficiency of the DVR depends on the performance of the efficiency...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012