Dependence of acoustic attenuation of hearing protectors on incident sound level.
نویسنده
چکیده
The relationship between incident sound level and acoustic attenuation for four types of earplug and four types of earmuff have been investigated using freshly prepared and instrumented cadaver ears. Pure tones and 1/3-octave bands of random noise in the frequency range 125-8000 Hz were employed as steady-state stimuli with sound pressure levels between 75 and 125 dB. Impulses with peak sound levels in the range 135-175 dB(P) were also presented. For the steady-state signals employed, the eight hearing protectors have been shown to have constant attenuation characteristics over the range of incident sound levels investigated. This was also the case for the six conventional protectors (with intentionally linear characteristics) for the impulse stimuli. The two intentionally amplitude-sensitive protectors provided attenuation which increased with incident sound level for impulse noises. Comparison of the protector attenuation-frequency characteristics determined for steady-state sounds shows good agreement with those obtained from subjective (threshold shift) national standard measurement procedures. It may be concluded, therefore, that the six conventional hearing protectors studied here have attenuation characteristics that are equal for incident sound levels at about 40 and 75 dB, and that they are constant for levels between 75 and 175 dB. Consequently, the results of national standard threshold-shift procedures, although measured at low sound levels, may be applied with confidence to occupations where hazardous high-level noises are present.
منابع مشابه
Active Noise Cancellation Vs Passive Sound Attenuation: Help or Hindrance?
Normal-hearing subjects show improved speech understanding when they wear conventional passive hearing protectors in noisy surroundings. In contrast, hearing-impaired subjects are at a disadvantage. Sound attenuation exacerbates the handicap from hearing loss (Abel et al., 1982). Level-dependent (active) hearing protectors which provide limited amplification of sounds below 85 dBA have the oppo...
متن کاملMeasurement of the attenuation characteristics of nonlinear hearing protective devices using the auditory brain stem response.
The purpose of this study was to determine the feasibility of using the auditory brain stem response (ABR) as a method of measuring the attenuation characteristics of nonlinear hearing protective devices. Sound field ABRs were recorded from seven normal hearing subjects with and without hearing protection. Three hearing protectors (two nonlinear and one linear) were evaluated. Test stimuli, con...
متن کاملA psychophysical evaluation of the dependence of hearing protector attenuation on noise level.
The attenuation characteristics of ten commercially available hearing protectors (five muffs and five plugs) were examined for 1/3-octave bands of noise centered at 1000, 2000, 3150, 4000, and 6300 Hz in ten normal-hearing young adults utilizing four psychophysical procedures. One of these procedures, the real-ear attenuation at threshold procedure described in the American standard for the eva...
متن کاملNoise pollution analysis in Tehran cement plant
Background : Cement industry has many process units. Basically all of these units can be considered as a source of noise. Since noise pollution is defined based on its offensive hearing effects, the importance of the noise sources depends directly on the number of workers in the unit. Materials and Methods : An experimental study has been done at Tehran cement factory to recogn...
متن کاملEffect of porosity on the characteristics of underwater acoustic sound absorbers using theoretical models
Porous materials have good acoustic damping characteristics over a wide frequency range. As for sound waves, many small-scale pores in the coating materials can convert underwater-coating to rough surfaces. The main property of porous absorbents is their resistance against incident sound wave that leads to damping effect. From a physical point of view, damping occurs due to friction between flu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of industrial medicine
دوره 36 1 شماره
صفحات -
تاریخ انتشار 1979