چکیده

Sound pressure level in-situ measurements are sensitive to standing-wave pressure minima and have the potential to result in over-amplification with risk to residual hearing in hearing-aid fittings. Forward pressure level (FPL) quantifies the pressure traveling toward the tympanic membrane and may be a potential solution as it is insensitive to ear-canal pressure minima. Derivation of FPL is dependent on a Thevenin-equivalent source calibration technique yielding source pressure and impedance. This technique is found to accurately decompose cavity pressure into incident and reflected components in both a hard-walled test cavity and in the human ear canal through the derivation of a second sound-level measure termed integrated pressure level (IPL). IPL is quantified by the sum of incident and reflected pressure amplitudes. FPL and IPL were both investigated as measures of sound-level entering the middle ear. FPL may be a better measure of middle-ear input because IPL is more dependent on middle-ear reflectance and ear-canal conductance. The use of FPL in hearing-aid applications is expected to provide an accurate means of quantifying high-frequency amplification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in situ calibration for hearing thresholds.

Quantifying how the sound delivered to the ear canal relates to hearing threshold has historically relied on acoustic calibration in physical assemblies with an input impedance intended to match the human ear (e.g., a Zwislocki coupler). The variation in the input impedance of the human ear makes such a method of calibration questionable. It is preferable to calibrate the acoustic signal in eac...

متن کامل

A method for calibration of bone driver transducers to measure the mastoid impedance.

When using bone vibrator transducers for clinical measurements, the transfer of energy from the bone driver depends on the impedance match between the driver and the load (human mastoid or otherwise) to which the driver will be applied. Current clinical calibration methods are incapable of quantifying this impedance mismatch, hence they fail to account for inter-subject variations of the energy...

متن کامل

An in-situ calibration method and the effects on stimulus frequency otoacoustic emissions

BACKGROUND The interference between the incoming sound wave and the acoustic energy reflected by the tympanic membrane (TM) forms a standing wave in human ear canals. The existence of standing waves causes various problems when measuring otoacoustic emissions (OAEs) that are soft sounds closely related with the functional status of the inner ear. The purpose of this study was to propose an in-s...

متن کامل

The Effect of Three-Dimensional Model on Anatomy Learning of Middle Ear

Purpose: The aim of this study was to study the effect of three-dimensional model in learning the anatomy of middle ear. Materials and Methods: The study was conducted at Artesh University of Medical Sciences in 3 phases in 2007: 1- preparation of three-dimensional model with reference to the Gray's Anatomy for Students (2005-1st edition), 2- dividing medical and nursing students into 4 grouos ...

متن کامل

Calibration of Area-Reduction Empirical Method for Dam Reservoir

The mathematical model of Area-Reduction empirical method is written through MATLAB software. Three periods of the hydrologic survey are required to run, calibrate and validatethe model. The Dez Dam, which is one of the most significant dams of the Middle East with three periods of hydrographic surveys in 1972, 2002 and 2011, has been chosen for the investigation. The annual average of the inpu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 126 6  شماره 

صفحات  -

تاریخ انتشار 2009