The effect of the design of the femoral component on the conformity of the patellofemoral joint in total knee replacement.
نویسندگان
چکیده
One of the most controversial issues in total knee replacement is whether or not to resurface the patella. In order to determine the effects of different designs of femoral component on the conformity of the patellofemoral joint, five different knee prostheses were investigated. These were Low Contact Stress, the Miller-Galante II, the NexGen, the Porous-Coated Anatomic, and the Total Condylar prostheses. Three-dimensional models of the prostheses and a native patella were developed and assessed by computer. The conformity of the curvature of the five different prosthetic femoral components to their corresponding patellar implants and to the native patella at different angles of flexion was assessed by measuring the angles of intersection of tangential lines. The Total Condylar prosthesis had the lowest conformity with the native patella (mean 8.58 degrees ; 0.14 degrees to 29.9 degrees ) and with its own patellar component (mean 11.36 degrees ; 0.55 degrees to 39.19 degrees ). In the other four prostheses, the conformity was better (mean 2.25 degrees ; 0.02 degrees to 10.52 degrees ) when articulated with the corresponding patellar component. The Porous-Coated Anatomic femoral component showed better conformity (mean 6.51 degrees ; 0.07 degrees to 9.89 degrees ) than the Miller-Galante II prosthesis (mean 11.20 degrees ; 5.80 degrees to 16.72 degrees ) when tested with the native patella. Although the Nexgen prosthesis had less conformity with the native patella at a low angle of flexion, this improved at mid (mean 3.57 degrees ; 1.40 degrees to 4.56 degrees ) or high angles of flexion (mean 4.54 degrees ; 0.91 degrees to 9.39 degrees ), respectively. The Low Contact Stress femoral component had the best conformity with the native patella (mean 2.39 degrees ; 0.04 degrees to 4.56 degrees ). There was no significant difference (p > 0.208) between the conformity when tested with the native patella or its own patellar component at any angle of flexion. The geometry of the anterior flange of a femoral component affects the conformity of the patellofemoral joint when articulating with the native patella. A more anatomical design of femoral component is preferable if the surgeon decides not to resurface the patella at the time of operation.
منابع مشابه
The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty
Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...
متن کاملAnthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population
Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...
متن کاملDistal Femoral Valgus Cut Errors in Total Knee Replacement
The causes of malalignment in total knee arthroplasty can be categorized into three different groups; 1) Errors in bone cuts 2) Errors in implant fixations, and 3) The method of setting down the cutting guides (1). We would like to announce that more several distal femoral valgus cut errors may occur during total knee replacement.
متن کاملRelationship between Femoral Intercondylar Notch Narrowing on Radiography and Anatomical and Histopathologic Integrity of Anterior Cruciate Ligament in Patients Undergoing Total Knee Replacement Surgery
Abstract Introduction: The presence of cruciate ligaments are very important for normal knee kinematics. Knee arthroplasty prostheses, in which these ligaments are maintained, have better kinematics. The aim of the present study was to investigate the association between femoral intercondylar notch narrowing in radiography and clinical and histopathologic integrity of anterior cruciate li...
متن کاملStress Fracture of the Lateral Femoral Condyle afterTotal Knee Arthroplasty
Background: This is to assess one of the rare complications after total knee replacement and to assess risk factors of failure.Methods: 11 patients with varus knee and an average age of 67 years underwent TKA between 2005 and 2013. All patients returned with a sudden sharp knee pain, disability to walk and significant decrease in ROM about 4 to 8 weeks after surgery. Radiographic examination re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 89 3 شماره
صفحات -
تاریخ انتشار 2007