Potentiometric ion- and bio-selective electrodes based on asymmetric cellulose acetate membranes.

نویسندگان

  • G S Cha
  • M E Meyerhoff
چکیده

The potentiometric response properties of ammonium-, carbonate-, and proton-selective electrodes prepared by incorporating appropriate neutral carriers within novel asymmetric cellulose acetate membranes are reported. The membranes are formed by first casting a thin layer of cellulose triacetate without carrier, hydrolyzing one side of this film with base, and then on the other side casting a second layer of cellulose triacetate containing the membrane active components. The resulting asymmetric ion-selective membranes function equivalently, in terms of selectivity and response slopes, to non-asymmetric cellulose triacetate membranes and conventional poly(vinyl chloride)-based membranes. The hydrolyzed surface of the asymmetric membranes can be activated in aqueous solution with carbonyldiimidazole for the direct immobilization of proteins on the surface of the membranes, without loss in potentiometric ion-response. As an example, the immobilization of urease on the surfaces of ammonium- and carbonate-selective membranes yields potentiometric bio-selective urea-probes with desirable dynamic response properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbon Nanotubes-Based Potentiometric Bio-Sensors for Determination of Urea

The possibility of using disposable plastic-carbon potentiometric sensors as enzyme biosensors was examined. Urease enzyme was immobilized on poly(vinyl chloride) based Hor NH4-selective membranes using cellulose acetate. This approach has resulted in a potentiometric response on changing the pH of the solution or NH4 ion content due to an enzymatic reaction that occurs between urease and urea....

متن کامل

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

The Ultrafiltration Performance of Cellulose Acetate Asymmetric Membranes: A New Perspective on the Correlation with the Infrared Spectra

Integral asymmetric cellulose acetate (CA) membranes were casted by phase-inversion with formamide varying content - 22, 30 and 34% - as pore promoter. These membranes, CA-22, CA-30 and CA-34, were analyzed by infrared spectroscopy in attenuated total reflection mode (ATR-FTIR) to investigate the porous membrane matrix influence on the polymer/water/solute interactions and the selective ultrafi...

متن کامل

Synthesis of Calcium Fluoride Ultrafine Particles for the Preparation of Integral Asymmetric Cellulose Acetate/Calcium Fluoride Membranes

The present work reports on the synthesis of cellulose acetate (CA) asymmetric membranes with the incorporation of inorganic fluorides, CaF2 particles. These fillers of polymeric composites can, according to the literature, promote the ordering of the polymer matrix, which can lead to interesting permeation properties. In order to achieve that, fluorite (CaF2 ) fine particles were prepared by a...

متن کامل

Enzymatic hydrolysis of sucrose in a dead-end stirred cell membrane bio-reactor using asymmetric cellulose acetate membranes

( Asymmetric cellulose acetate membranes have been prepared and characterized in the laboratory with a view to use them in membrane bio-reactors. Enzymatic hydrolysis of sucrose has been investigated in a dead-end stirred cell type membrane bio-reactor using these membranes. Effect of different operating variables such as substrate concentration, enzyme loading, flow rate and working volume hav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 36 1-2  شماره 

صفحات  -

تاریخ انتشار 1989