Intercomparison of Hantzsch and fiber-laser-induced-fluorescence formaldehyde measurements

نویسندگان

  • J. Kaiser
  • X. Li
  • R. Tillmann
  • I. Acir
  • F. Holland
  • F. Rohrer
  • R. Wegener
  • F. N. Keutsch
چکیده

Two gas-phase formaldehyde (HCHO) measurement techniques, a modified commercial wet-chemical instrument based on Hantzsch fluorimetry and a custombuilt instrument based on fiber laser-induced fluorescence (FILIF), were deployed at the atmospheric simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) to compare the instruments’ performances under a range of conditions. Thermolysis of para-HCHO and ozonolysis of 1-butene were used as HCHO sources, allowing for calculations of theoretical HCHO mixing ratios. Calculated HCHO mixing ratios are compared to measurements, and the two measurements are also compared. Experiments were repeated under dry and humid conditions (RH< 2 % and RH> 60 %) to investigate the possibility of a water artifact in the FILIF measurements. The ozonolysis of 1-butene also allowed for the investigation of an ozone artifact seen in some Hantzsch measurements in previous intercomparisons. Results show that under all conditions the two techniques are well correlated (R2 ≥ 0.997), and linear regression statistics show measurements agree with within stated uncertainty (15 % FILIF+ 5 % Hantzsch). No water or ozone artifacts are identified. While a slight curvature is observed in some Hantzsch vs. FILIF regressions, the potential for variable instrument sensitivity cannot be attributed to a single instrument at this time. Measurements at low concentrations highlight the need for a secondary method for testing the purity of air used in instrument zeroing and the need for further FILIF White cell outgassing experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intercomparison of four different in-situ techniques for ambient formaldehyde measurements in urban air

Results from an intercomparison of several currently used in-situ techniques for the measurement of atmospheric formaldehyde (CH2O) are presented. The measurements were carried out at Bresso, an urban site in the periphery of Milan (Italy) as part of the FORMAT-I field campaign. Eight instruments were employed by six independent research groups using four different techniques: Differential Opti...

متن کامل

Ambient formaldehyde measurements made at a remote marine boundary layer site during the NAMBLEX campaign – a comparison of data from chromatographic and modified Hantzsch techniques

Ambient formaldehyde concentrations are reported from the North Atlantic Marine Boundary Layer Experiment (NAMBLEX) campaign at Mace Head on the west coast of Eire during August 2002. The results from two techniques, using direct determination via gas chromatography and the Hantzsch technique, show similar trends but a significant off set in concentrations. For westerly air flows characteristic...

متن کامل

Interactive comment on “A new airborne laser-induced fluorescence instrument for in situ detection of Formaldehyde throughout the troposphere and lower stratosphere” by M. Cazorla et al

This paper presents a summary of a new laser-induced fluorescence instrument for airborne measurements of formaldehyde. As mentioned in the paper, accurate and precise measurements of formaldehyde are needed as they can provide an important constraint to test current models of atmospheric chemistry as well as provide retrieval validation for satellite measurements. The paper provides a detailed...

متن کامل

Field intercomparison of a novel optical sensor for formaldehyde quantification.

A one-week in situ intercomparison campaign was completed on the Rice University campus for measuring HCHO using three different techniques, including a novel optical sensor based on difference frequency generation (DFG) operating at room temperature. Two chemical derivatization methods, 2,4-dinitrophenylhydrazine (DNPH) and o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA), were deployed d...

متن کامل

Laser-induced fluorescence of formaldehyde hot bands in flames.

Laser-induced fluorescence and excitation spectra of formaldehyde in the A-X 4(1)(0) band at 370 nm are recorded in the primary flame front of a Bunsen flame. An examination of partition functions shows that this excitation can minimize temperature bias for formaldehyde in situ diagnostic measurements.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014