Sorbent track: Quantitative monitoring of adsorbed VOCs under in-situ plasma exposure

نویسندگان

  • Zixian Jia
  • Antoine Rousseau
چکیده

Sorbent-TRACK is a new device developed to monitor adsorption and surface oxidation of pollutants under direct plasma exposure. It is based on direct transmitted Fourier Transformed Infrared (FTIR) spectroscopy. A pyrex reactor under controlled gas pressure and composition is inserted on the infrared beam of a commercially available Nicolet 5700 FTIR spectrometer. A substrate holder is located on the optical path of the infrared beam. A thin pellet of a dedicated catalyst (CeO2 in the present work) is inserted in a substrate holder and can be exposed to direct plasma treatment using a Dielectric Barrier Discharge. The time resolution of Sorbent-TRACK is limited by the time resolution of the Nicolet 5700 FTIR spectrometer and close to 30 s. The dynamic of the adsorption and plasma oxidation of acetone and isopropanol on CeO2 are studied and intermediates are monitored. Performances and sensitivity of Sorbent-TRACK are reported Adsorption and oxidation of acetone leads to production of adsorbed isobutene and acetic acid, where oxidation of isopropanol gives mainly to adsorbed acetone, mesityl oxide and acetate. An increase of the plasma power leads to an increase of the isopropanol and acetone oxidation rate and a related increase of the production of adsorbed intermediates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Model Development and Validation of Personal Exposure to Volatile Organic Compound Concentrations

BACKGROUND Direct measurement of exposure to volatile organic compounds (VOCs) via personal monitoring is the most accurate exposure assessment method available. However, its wide-scale application to evaluating exposures at the population level is prohibitive in terms of both cost and time. Consequently, indirect measurements via a combination of microenvironment concentrations and personal ac...

متن کامل

The progress mechanism of track geometrical irregularity focusing on hanging sleepers

This topic is very traditional and basically has been concerned for a long time. A lot of sophisticated vehicle/track interaction model and track dynamic deterioration model have been developed so far. The author also developed a track settlement progress model comprising a vehicle/track interaction model and a track settlement law. Hanging sleepers are usually caused more or less by the dyn...

متن کامل

Effectiveness of Portable Room Air Cleaners for Control of Volatile Organic Compounds in Indoor Air

IAQ T1S3) Eleven commercially available portable room air cleaners have been tested on a mixture of 16 representative volatile organic compounds (VOC) in a full-scale stainless steel chamber and their initial VOC removal efficiencies have been evaluated. These products use different gas-phase contaminant removal technologies including adsorption, photocatalytic oxidation under UV irradiation (U...

متن کامل

A Novel Methodology to Evaluate Health Impacts Caused by VOC Exposures Using Real-Time VOC and Holter Monitors

While various volatile organic compounds (VOCs) are known to show neurotoxic effects, the detailed mechanisms of the action of VOCs on the autonomic nervous system are not fully understood, partially because objective and quantitative measures to indicate neural abnormalities are still under development. Nevertheless, heart rate variability (HRV) has been recently proposed as an indicative meas...

متن کامل

N-octyl-modified magnetite NPs for optimization of solid phase extraction for trace analysis of phenytoin in real samples

objective: Phenytoin is an anti-seizure medication used to treat epilepsy, as well as to control arrhythmias (irregular heartbeat) and to treat migraine headaches and nerve pain. It is recommended to determine the amount of this drug in the blood to control the seizure and prevent its toxicity. In the present study, a sensitive and simple procedure based on the dispersive solid phase extraction...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016