The performance of fluorescence and reflectance spectroscopy for the in vivo diagnosis of cervical neoplasia; point probe versus multispectral approaches.

نویسندگان

  • J Adrian Freeberg
  • J L Benedet
  • Calum MacAulay
  • Loyd A West
  • Michele Follen
چکیده

OBJECTIVE This review evaluates the diagnostic efficacy of fluorescence spectroscopy, reflectance spectroscopy, and their combination that use both point probe and multispectral imaging approaches in diagnosing cervical neoplasia in vivo. METHODS Articles were selected for this review from a literature search which report the performance of fluorescence and reflectance spectroscopy devices in diagnosing cervical neoplasia in vivo. This analysis focused on the comparison of point probe versus multispectral approaches; the use of fluorescence, reflectance, and their combination; and finally the types of populations that have been studied for in vivo diagnosis of squamous intraepithelial lesions (SIL). RESULTS Twenty-six studies were included and their heterogeneity precluded formal meta-analysis. Though point probes were expected to have greater specificity and multispectral approaches greater sensitivity, there was considerable overlap in the performance of point probe and multispectral devices. There were few studies that studied fluorescence spectroscopy alone and reflectance spectroscopy alone. Combined fluorescence and reflectance approaches showed considerable overlap among point probe and multispectral devices. The overlap of performance suggests that fluorescence and reflectance may have similar performance. Currently the paucity of data precludes definitive conclusions regarding the additive effect of both approaches. Only two of twenty-six trials have recruited patients with no history of an abnormal Papanicolaou smear (screening populations) and twenty-four trials include patients with a range of cervical abnormalities from atypia to cancer (diagnostic populations). DISCUSSION Optical spectroscopy using a point probe and multispectral approaches appears to overlap in performance. Fluorescence and reflectance spectroscopies examine different aspects of epithelial-stromal biology and appear to yield similar diagnostic performance. While intuitively appealing, their combination may or may not be additive. There have been few studies of these technologies in screening populations. Better definitions of device trial design and reporting requirements would facilitate combining analyses to formally examine performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorescence and reflectance device variability throughout the progression of a phase II clinical trial to detect and screen for cervical neoplasia using a fiber optic probe.

Large phase II trials of fluorescence and reflectance spectroscopy using a fiber optic probe in the screening and diagnostic settings for detecting cervical neoplasia have been conducted. We present accrual and histopathology data, instrumentation, data processing, and the preliminary results of interdevice consistencies throughout the progression of a trial. Patients were recruited for either ...

متن کامل

Spectral Separation of Quantum Dots within Tissue Equivalent Phantom Using Linear Unmixing Methods in Multispectral Fluorescence Reflectance Imaging

Introduction Non-invasive Fluorescent Reflectance Imaging (FRI) is used for accessing physiological and molecular processes in biological media. The aim of this article is to separate the overlapping emission spectra of quantum dots within tissue-equivalent phantom using SVD, Jacobi SVD, and NMF methods in the FRI mode. Materials and Methods In this article, a tissue-like phantom and an optical...

متن کامل

Reflectance spectroscopy for in vivo detection of cervical precancer.

Optical technologies, in particular fluorescence spectroscopy, have shown the potential to provide improved detection methods for cervical neoplasia that are sensitive and cost effective through accurate, objective, instantaneous point-of-care diagnostic tools. The specific goals of this study were to analyze reflectance spectra of normal and neoplastic cervical tissue in vivo and to evaluate t...

متن کامل

Multispectral digital colposcopy for in vivo detection of cervical cancer.

We present a multispectral digital colposcope (MDC) to measure multispectral autofluorescence and reflectance images of the cervix by using an inexpensive color CCD camera. The diagnostic ability of the MDC was evaluated by application of MDC spectral response to fluorescence and reflectance spectra measured from a large clinical trial. High diagnostic performance was achieved by use of only tw...

متن کامل

Optical techniques for cervical neoplasia detection

This paper provides an overview of the current research in the field of optical techniques for cervical neoplasia detection and covers a wide range of the existing and emerging technologies. Using colposcopy, a visual inspection of the uterine cervix with a colposcope (a binocular microscope with 3- to 15-fold magnification), has proven to be an efficient approach for the detection of invasive ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gynecologic oncology

دوره 107 1 Suppl 1  شماره 

صفحات  -