False alarm reduction in critical care.
نویسندگان
چکیده
High false alarm rates in the ICU decrease quality of care by slowing staff response times while increasing patient delirium through noise pollution. The 2015 PhysioNet/Computing in Cardiology Challenge provides a set of 1250 multi-parameter ICU data segments associated with critical arrhythmia alarms, and challenges the general research community to address the issue of false alarm suppression using all available signals. Each data segment was 5 minutes long (for real time analysis), ending at the time of the alarm. For retrospective analysis, we provided a further 30 seconds of data after the alarm was triggered. A total of 750 data segments were made available for training and 500 were held back for testing. Each alarm was reviewed by expert annotators, at least two of whom agreed that the alarm was either true or false. Challenge participants were invited to submit a complete, working algorithm to distinguish true from false alarms, and received a score based on their program's performance on the hidden test set. This score was based on the percentage of alarms correct, but with a penalty that weights the suppression of true alarms five times more heavily than acceptance of false alarms. We provided three example entries based on well-known, open source signal processing algorithms, to serve as a basis for comparison and as a starting point for participants to develop their own code. A total of 38 teams submitted a total of 215 entries in this year's Challenge. This editorial reviews the background issues for this challenge, the design of the challenge itself, the key achievements, and the follow-up research generated as a result of the Challenge, published in the concurrent special issue of Physiological Measurement. Additionally we make some recommendations for future changes in the field of patient monitoring as a result of the Challenge.
منابع مشابه
Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform
BACKGROUND Over the past two decades, high false alarm (FA) rates have remained an important yet unresolved concern in the Intensive Care Unit (ICU). High FA rates lead to desensitization of the attending staff to such warnings, with associated slowing in response times and detrimental decreases in the quality of care for the patient. False arrhythmia alarms are commonly due to single channel E...
متن کاملFalse alarm reduction in critical care
High false alarm rates in the ICU decrease quality of care by slowing staff response times while increasing patient delirium through noise pollution. The 2015 PhysioNet/Computing in Cardiology Challenge provides a set of 1250 multi-parameter ICU data segments associated with critical arrhythmia alarms, and challenges the general research community to address the issue of false alarm suppression...
متن کاملEditorial: False Alarm Reduction in Critical Care
High false alarm rates in the ICU decrease quality of care by slowing staff response times while increasing patient delirium through noise pollution. The 2015 Physio-Net/Computing in Cardiology Challenge provides a set of 1,250 multi-parameter ICU data segments associated with critical arrhythmia alarms, and challenges the general research community to address the issue of false alarm suppressi...
متن کاملAttitudes and practices related to clinical alarms.
BACKGROUND The number of devices with alarms has multiplied in recent years, causing alarm fatigue in bedside clinicians. Alarm fatigue is now recognized as a critical safety issue. OBJECTIVE To determine if attitudes and practices related to clinical alarms have changed since 2005. METHODS The Healthcare Technology Foundation's Clinical Alarms Committee developed an online survey for hospi...
متن کاملAlarm algorithms in critical care monitoring.
The alarms of medical devices are a matter of concern in critical and perioperative care. The frequent false alarms not only are a nuisance for patients and caregivers but can also compromise patient safety and effectiveness of care. The development of alarm systems has lagged behind the technological advances of medical devices over the last 20 years. From a clinical perspective, major improve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological measurement
دوره 37 8 شماره
صفحات -
تاریخ انتشار 2016