New ultraviolet (340 nm) method for assay of uric acid in serum or plasma.
نویسندگان
چکیده
We propose a novel enzymatic method for assay of uric acid at 340 nm, which eliminates several disadvantages of both the colorimetric and enzymatic methods now in common use. Here, uric acid is catalytically oxidized to allantoin and hydrogen peroxide. The peroxide is reacted with ethanol in the presence of catalase to form acetaldehyde and water, and the acetaldehyde is reduced by NADH in the presence of alcohol dehydrogenase to ethanol. The decrease in absorbance at 340 nm caused by oxidation of NADH is directly proportional to the concentration of uric acid in the sample. Measurement of the change in absorbance between 20 and 200 s eliminates the need for a serum blank measurement. Absorbance and concentration are linearly related to 120 mg of uric acid per liter. The new method was compared with the uricase method in which decomposition of uric acid at 293 nm is directly measured. The results for the 47 patients' sera so examined can be expressed by the linear equation y340 = 1.0078x293 + 0.122 (r = 0.9984).
منابع مشابه
Use of 3,5-dichloro-2-hydroxybenzenesulfonic acid/4-aminophenazone chromogenic system in direct enzymic assay of uric acid in serum and urine.
A new direct colorimetric procedure for uric acid assay in serum or urine is described, utilizing a 3,5-dichloro-2-hydroxybenzene sulfonic acid/4-aminophenazone chromogenic system in the presence of horseradish peroxidase and uricase from Aspergillus flavus. This chromogen system has a high absorptivity, affording useful results with sample/reagent volume ratios as low as 0.025. The procedure i...
متن کاملCrocin Bleaching Assay Using Purified Di-gentiobiosyl Crocin (a-crocin) from Iranian Saffron
Objective(s) Crocin bleaching assay (CBA) is a new method for determination of antioxidant capacity. In CBA, addition of hydrogen to the conjugated double bonds of crocin results in reduction of crocin and increase in the absorbance at 440 nm, which is considered as a measure of antioxidant potential. Here CBA method was set up using di-gentiobiosyl crocin or a-crocin from Iranian saffron. The...
متن کاملOptimal Wavelength Selection in Ultraviolet Spectroscopy for the Estimation of Toxin Reduction Ratio during Hemodialysis
Introduction The concentration of substances, including urea, creatinine, and uric acid, can be used as an index to measure toxic uremic solutes in the blood during dialysis and interdialytic intervals. The on-line monitoring of toxin concentration allows for the clearance measurement of some low-molecular-weight solutes at any time during hemodialysis.The aim of this study was to determine the...
متن کاملAssociation of Uric Acid with Antioxidant Capacity of Plasma in Patients with Type 2 Diabetic Nephropathy
Background: The role of attenuation in antioxidant capacity or expansion of pro-oxidant/oxidant is well known for the development of stress oxidative. The aim of this study was to evaluate the plasma antioxidant capacity along with uric acid in patients with diabetic nephropathy (DN+) and without diabetic nephropathy (DN-). Materials and Methods: The research population included 88 patients ...
متن کاملDetermination of L- Ascorbic Acid in Plasma by Voltammetric Method
Voltammetric techniques have been considered as important methods among the analytical techniques used for the identification and determination of trace concentrations of many biological molecules such as L-ascorbic acid (AA). L-ascorbic acid is an electro-active molecule, though it is difficult to determine its value directly with a majority of electrodes made of carbon and transition metals, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 24 4 شماره
صفحات -
تاریخ انتشار 1978