Automated responsiveness test and bispectral index monitoring during propofol and propofol/N2O sedation.

نویسندگان

  • A G Doufas
  • M Bakhshandeh
  • G S Haugh
  • A R Bjorksten
  • R Greif
  • D I Sessler
چکیده

BACKGROUND Sedation practice, especially when non-anaesthesia personnel are involved, requires efficient anaesthetic depth monitoring. Therefore, we used prediction probability (PK) to evaluate the performance of the bispectral index (BIS) of the EEG and automated responsiveness test (ART) to predict sedation depth and loss of subject's responsiveness during propofol sedation, with and without N2O. METHODS Twenty volunteers were studied during propofol administration with (N2O) and without (Air) N2O. The protocol consisted of sequential 15-min cycles. After a control period, propofol was infused to a target effect-site concentration of 0.25 microg/ml (N2O) or 1.5 microg/ml (Air), which was subsequently increased by 0.25 or 0.5 microg/ml, respectively, until loss of responsiveness was detected by loss of response to command [observer's assessment of alertness/sedation (OAA/S) score <or= 2]. RESULTS Deeply sedated patients did not respond to ART indicating that the sensitivity was 1.0 with or without N2O. The specificity of ART was 0.24 with Air and 0.98 with N2O. The BIS was better than ART in predicting OAA/S score (PK = 0.84 vs. 0.77) and loss of responsiveness (PK = 0.87 vs. 0.69) during the Air trial. Nitrous oxide decreased the performance of BIS in predicting OAA/S score (PK = 0.76), but increased the performance of ART to predict loss of responsiveness (PK = 0.85). CONCLUSION BIS and ART comparably predict sedation and loss of responsiveness. However, ART, because of its resistance to false-normal responses, might prove to be more useful on an individual patient basis - especially in the presence of agents that impair BIS sensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extended Monitoring of the Sedated Patient: Bispectral Index, Narcotrend® and Automated Responsiveness Monitor

It has been demonstrated that a processed EEG derivative may reflect the patient’s level of consciousness during endoscopic sedation. However, to date a clinical benefit of EEG monitoring with respect to relevant safety parameters in routine gastrointestinal endoscopy has not been demonstrated. During long-lasting procedures (e.g. ERCP, ESD) a propofol-sparing effect has been shown, but a benef...

متن کامل

Extended monitoring of the sedated patient: bispectral index, Narcotrend and automated responsiveness monitor.

It has been demonstrated that a processed EEG derivative may reflect the patient's level of consciousness during endoscopic sedation. However, to date a clinical benefit of EEG monitoring with respect to relevant safety parameters in routine gastrointestinal endoscopy has not been demonstrated. During long-lasting procedures (e.g. ERCP, ESD) a propofol-sparing effect has been shown, but a benef...

متن کامل

Automated responsiveness test (ART) predicts loss of consciousness and adverse physiologic responses during propofol conscious sedation.

BACKGROUND The authors evaluated a device designed to provide conscious sedation with propofol (propofol-air), or propofol combined with 50% nitrous oxide (N2O; propofol-N2O). An element of this device is the automated responsiveness test (ART), a method for confirming that patients remain conscious. The authors tested the hypotheses that the ART predicts loss of consciousness and that failure ...

متن کامل

Correlation between Bispectral Index and Predicted Effect-site Concentration of Propofol in Different Levels of Target-Controlled, Propofol Induced Sedation in Healthy Volunteers

Introduction: Bispectral Index is an objective tool to assess electroencephalographic activity and measure the effect of certain sedatives and hypnotics on the brain. In addition, there are certain subjective tools such as the observer's assessment of alertness and sedation which are used. The correlation between BIS and the concentration of propofol in the brain, and the relationship between t...

متن کامل

Effects of bispectral index monitoring as an adjunct to nurse-administered propofol combined sedation during colonoscopy: a randomized clinical trial.

BACKGROUND/AIMS The efficacy of bispectral index (BIS) monitoring during colonoscopic sedation is debated. We aimed to determine whether BIS monitoring was useful for propofol dose titration, and to evaluate differences in sedative administration between expert and inexperienced medical personnel during colonoscopy procedures that required moderate sedation. METHODS Between February 2012 and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta anaesthesiologica Scandinavica

دوره 47 8  شماره 

صفحات  -

تاریخ انتشار 2003