Distal Lower Extremities: Prospective Comparison of 2D Time-of-Flight, 3D Time-Resolved Contrast-Enhanced MR Angiography, and 3D Bolus Chase Contrast-Enhanced MR Angiography

نویسندگان

  • W. Y. Hahn
  • E. M. Hecht
  • B. Friedman
  • V. S. Lee
چکیده

W. Y. Hahn, E. M. Hecht, B. Friedman, V. S. Lee NYU Medical Center, New York, NY, United States SYNOPSIS: Magnetic resonance angiography of the calf and pedal arteries is challenging due to the issues of venous contamination and small vessel size. Therefore, contrast-enhanced MRA is typically supplemented with TOF imaging below the knee. In this study, we compared the conventional TOF sequence with 3D contrastenhanced time-resolved MRA and 3D bolus chase MRA for calf and pedal imaging. Both 3D methods are superior to TOF imaging in the evaluation of arterial length and stenosis grade. Furthermore, the time-resolved technique adds important dynamic information about blood flow direction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Head and neck paragangliomas: improved tumor detection using contrast-enhanced 3D time-of-flight MR angiography as compared with fat-suppressed MR imaging techniques.

BACKGROUND AND PURPOSE MR imaging techniques have proved their efficacy in imaging the head and neck region. In this study, we compared T1-weighted, dual T2-weighted, and fat-suppressed MR imaging and unenhanced and contrast-enhanced 3D time-of-flight MR angiography sequences for detection of head and neck paragangliomas. METHODS Thirty-one patients with 70 paragangliomas were examined. Four ...

متن کامل

Clinical Usefulness of Contrast Enhanced 3D-MR Angiography using Automated Stepping Table Method

Introduction Image quality of MR angiography (MRA) has been substantially improved with fast three-dimensional (3D) MRA acquired during the first passage of a bolus injection of the contrast medium. For clinical evaluation of vascular disorders such as atherosclerotic obstruction (ASO) and aortic aneurysm, a long anatomic region including abdomen and lower extremities has to be imaged, Contrast...

متن کامل

Comparison of High Spatial Resolution Time-Resolved 3D Con- trast-Enhanced MR Angiography

Introduction: Recently, computed tomographic angiography (CTA) has become widely used for lower extremity arterial runoff imaging, in part because of high spatial resolution and extended coverage obtained with continuous table movement during the exam. However, even with optimized technique, 2-3% of studies are nondiagnostic because of calcification, poor contrast opacification, or venous conta...

متن کامل

Dedicated Calf MRA at 3T: Comparison of time-resolved MR Angiography with interleaved stochastic trajectories (TWIST) with standard high-resolution 3D contrast enhance MR Angiography (HR ceMRA)

¶ Figure 3: Calf station of left lower limb in patient with normal runoff arteries. (A) TWIST demonstrates focal occlusion of the distal anterior tibial artery (arrow) and a high grade stenosis of the distal posterior tibial artery (arrowhead) (B) HR ceMRA demonstrating normally appearing runoff arteries. Dedicated Calf MRA at 3T: Comparison of time-resolved MR Angiography with interleaved stoc...

متن کامل

Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-TOF MR venography and digital subtraction angiography.

BACKGROUND AND PURPOSE The diagnosis of dural sinus thrombosis is often difficult because of its variable and nonspecific clinical presentation and the overlapping signal intensities of thrombosis and venous flow on conventional MR images and MR venograms. We compared 3D contrast-enhanced magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with 2D time-of-flight (TOF) MR venography, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002