Quantitative myocardial infarction on delayed enhancement MRI. Part II: Clinical application of an automated feature analysis and combined thresholding infarct sizing algorithm.

نویسندگان

  • Li-Yueh Hsu
  • W Patricia Ingkanisorn
  • Peter Kellman
  • Anthony H Aletras
  • Andrew E Arai
چکیده

PURPOSE To compare global and regional myocardial infarction (MI) measurements on clinical gadolinium-enhanced magnetic resonance (MR) images using human manual contouring and a computer algorithm previously validated by histopathology, and to study the degree to which visual assessment and human contouring of infarct extent agreed with the computer algorithm. MATERIALS AND METHODS Infarct size in 20 patients was measured by human manual contouring and with an automated feature analysis and combined thresholding (FACT) computer algorithm. Short-axis slices were divided into myocardial sectors for regional analysis. Extent of infarction was also graded visually by consensus of expert readers and compared to human and computer contouring. RESULTS Despite good correlations (R = 0.93-0.95) between human contouring and the FACT algorithm, human contouring overestimated infarct size by 3.8% of the left ventricle (23.8% of the MI) area (P < 0.001). Human contouring also overestimated the circumferential extent, transmural extent, and extent of infarction within a sector by 7.1%, 18.2%, and 27.9%, respectively (all P < 0.001). Both consensus reading and human contouring overestimated infarct grades compared with the FACT algorithm (P = 0.002 and P < 0.001). CONCLUSION Clinically relevant overestimation of MI can occur in visual interpretation and in human manual contouring, particularly with respect to extent of infarction on a regional basis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative myocardial infarction on delayed enhancement MRI. Part I: Animal validation of an automated feature analysis and combined thresholding infarct sizing algorithm.

PURPOSE To develop a computer algorithm to measure myocardial infarct size in gadolinium-enhanced magnetic resonance (MR) imaging and to validate this method using a canine histopathological reference. MATERIALS AND METHODS Delayed enhancement MR was performed in 11 dogs with myocardial infarction (MI) determined by triphenyltetrazolium chloride (TTC). Infarct size on in vivo and ex vivo imag...

متن کامل

Automatic detection and size quantification of infarcts by myocardial perfusion SPECT: clinical validation by delayed-enhancement MRI.

UNLABELLED We aimed to validate the accuracy of a new automated myocardial perfusion SPECT quantification based on normal limits for detection and sizing of infarcts, using delayed-enhancement MRI (DE-MRI) as a gold standard. METHODS Eighty-two immediate (201)Tl rest scans and 26 (201)Tl delayed redistribution scans were compared with resting DE-MRI scans acquired within 24 h of SPECT acquisi...

متن کامل

Detection of Cardiac Infarction in MRI C-SENC Images

Composite Strain Encoding (C-SENC) is an Magnetic Resonance Imaging (MRI) technique for acquiring simultaneous viability and functional and images of the heart. It combines two imaging techniques, Delayed Enhancement (DE) and Strain Encoding (SENC). In this work, a novel multi-stage method is proposed to identify ventricular infarction in the functional and viability images provided by C-SENC M...

متن کامل

Computerized Measurement of Myocardial Infarct Size on Contrast-Enhanced Magnetic Resonance Images

Purpose: To validate a computer algorithm for measuring myocardial infarct size on gadolinium enhanced MR images. The results of computer infarct sizing are studied on phase-sensitive and magnitude imaging against a histopathology reference. Materials and Methods: Validations were performed in 9 canine myocardial infarctions determined by triphenyltetrazolium chloride (TTC). The algorithm analy...

متن کامل

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 2006