Clinical validation of the AMTAS automated audiometer.

نویسندگان

  • Robert H Eikelboom
  • De Wet Swanepoel
  • Shahpar Motakef
  • Gemma S Upson
چکیده

OBJECTIVE To validate the air- and bone-conduction AMTAS automated audiometry system. DESIGN Prospective study. Test-retest reliability was determined by assessing adults with AMTAS air- and bone-conduction audiometry. Accuracy was determined by comparing AMTAS and manual audiometry conducted on adults. AMTAS testing was conducted in a quiet room and manual audiometry in a sound booth. STUDY SAMPLE Ten participants for test-retest reliability tests and 44 participants to determine accuracy were included. Participants had varying degrees of hearing loss. RESULTS For test-retest reliability the overall difference in air-conduction hearing thresholds (n = 119) was 0.5 dB. The spread of differences (standard deviation of absolute differences) was 4.9 dB. For bone-conduction thresholds (n = 99) the overall difference was - 0.2 dB, and the spread of differences 4.5 dB. For accuracy the overall difference in air-conduction hearing thresholds (n = 509) between the two techniques was 0.1 dB. The spread of differences was 6.4 dB. For bone-conduction thresholds (n = 295) the overall difference was 0 dB, and the spread of differences 7.7 dB. CONCLUSIONS Variations between air- and bone-conduction audiometry for automated and manual audiometry were within normally accepted limits for audiometry. However, AMTAS thresholds were elevated but not significantly different compared to other contemporary studies that included an automated audiometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

OtoID: new extended frequency, portable audiometer for ototoxicity monitoring.

Portability of equipment is an increasingly important component in the practice of audiology. We report on a new device, the OtoID, that supports evidence-based ototoxicity testing protocols, provides capability for hearing testing on the hospital treatment unit, and can automate patient self-testing. The purpose of this article is to report on the validation and verification of the OtoID porta...

متن کامل

Pure-tone audiometry outside a sound booth using earphone attentuation, integrated noise monitoring, and automation.

OBJECTIVE Accessibility of audiometry is hindered by the cost of sound booths and shortage of hearing health personnel. This study investigated the validity of an automated mobile diagnostic audiometer with increased attenuation and real-time noise monitoring for clinical testing outside a sound booth. DESIGN Attenuation characteristics and reference ambient noise levels for the computer-base...

متن کامل

The new age of play audiometry: prospective validation testing of an iPad-based play audiometer

OBJECTIVE The timely diagnosis of hearing loss in the pediatric population has significant implications for a child's development. However, audiological evaluation in this population poses unique challenges due to difficulties with patient cooperation. Though specialized adaptations exist (such as conditioned play audiometry), these methods can be time consuming and costly. The objective of thi...

متن کامل

The instructional effectiveness of a web-based audiometry simulator.

With distance learning becoming more of a reality than a novelty in many undergraduate and graduate training programs, web-based clinical simulations can be identified as an instructional option in distance education that has both a sound pedagogical foundation and clinical relevance. The purpose of this article is to report on the instructional effectiveness of a web-based pure-tone audiometry...

متن کامل

Automated detection of coronavirus disease (COVID-19) by using data-mining techniques: a brief report

Background: The clinical field has vast sick data that has not been analyzed. Discovering a way to analyze this raw data and turn it into an information treasure can save many lives. Using data mining methods is an efficient way to analyze this large amount of raw data. It can predict the future with accurate knowledge of the past, providing new insights into disease diagnosis and prevention. S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of audiology

دوره 52 5  شماره 

صفحات  -

تاریخ انتشار 2013